Troubleshooting
4-47
4-4-16. Full current error / PFC over-current error (Error Code : E462, E484)
1. Test
items
1) Check the power connection. / Check the restart after power reset.
2) Install outdoor unit and check environment.
ĺ
Check for wire disconnection related to outdoor unit Inverter PCB and check the installation environment.
3) Check the indoor unit installation environment.
4) Check the opening of service valve.
2. Check
procedure
Yes
Outdoor unit installation and environment check.
ĺ
Check for normal operation at restart.
ĺ
End the
service.
1. Check for wire disconnection related to outdoor
unit Inverter PCB.
2. Remove obstacle on the inlet of outdoor unit and
secure the space.
3. Remove obstacle on the outlet of outdoor unit and
secure the space.
Check installation environment of indoor unit.
ĺ
check for normal operation at restart.
ĺ
End the
service.
1. Remove obstacle on the inlet and secure the space.
2. Remove obstacle on the outlet and secure the
space.
No
Is the outdoor unit installed properly?
After replacing the Inverter PCB of the outdoor unit, check for
normal startup.
ĺ
End the service.
Yes
No
Is the indoor unit installed properly?
Yes
Replace the compressor.
No
Yes
Power on 30 seconds after power off.
Open the valve.
No
Is service valve fully opened?
Is compressor running properly?