Troubleshooting
4-2
Samsung Electronics
4-1-2 Wired Remocon Error Display
- If an error occurs, ( ) is displayed on the wired remote controller.
- If you would like to see an error code, press the Test button.
Error mode
Contents
Error type
Indoor unit communication error
Communication error
Duplicated address setting error
Communication error
No response error address from indoor unit
Communication error
Indoor temperature sensor (open/short error)
Indoor sensor error
Indoor unit Eva In sensor (Open/Short)
Indoor sensor error
Indoor/outdoor communication error (1 min)
Communication error
Communication error between indoor/outdoor INV
l
MAIN MICOM (1 min)
Communication error
Outdoor temperature sensor error
Outdoor sensor error
COND temperature sensor error
Outdoor sensor error
[Inverter] Emission temperature sensor error
Outdoor sensor error
Detection of Indoor Freezing (when Comp. Stops)
Outdoor unit protection control error
Protection of Outdoor Overload (when Comp. Stops)
Outdoor unit protection control error
Emission temperature excessively high
Outdoor unit protection control error
High pressure blockage error
(Refrigerant completely Leakage error)
Self diagnostic error
Heating operation blocked
Self diagnostic error
Cooling operation blocked
Self diagnostic error
Outdoor fan 1 error
Self diagnostic error
[Inverter] Compressor startup error
Outdoor unit protection control error
[Inverter] Total current error/PFC over current error
Outdoor unit protection control error
OLP Overheat and Comp. Stop
Outdoor unit protection control error
[Inverter] IPM over current error
Outdoor unit protection control error
Compressor V limit error
Outdoor unit protection control error
DC LINK over/low voltage error
Outdoor unit protection control error