Troubleshooting
4-36
Samsung Electronics
*1.0WFSDVSSFOU&SSPS
&SSPS$PEF&
1. Test Item
1) Check the power supply. / Check the re-startup after the power is reset.
2) Check the outdoor unit installation environment.
ױ
Check the disconnection of the wires regarding the inverter PBA of the outdoor unit and check the installation environment.
ױ
At the site where several units were installed at the same time, check whether communication connections and pipes have been wrongly connected!
3) Check the indoor unit installation environment.
4) Check the opening of the service valve.
5) Check the compressor and the state of the compressor wire assembling.
6) Check for fault of the single compressor wire.
2. Check
procedure
Yes
Check the outdoor unit installation
environment.
ױ
Check everything is normal at
re-start
͑͟ױ͑
End the service.
1. Check the wire disconnection of the inverter
PBA of the outdoor unit.
2. Remove the obstacles of the suction pipes
of the outdoor unit and secure the space.
Check the indoor unit installation
environment.
͑ױ
Check everything is
normal at re-start.
ױ͑
End the service.
1. Remove the obstacles of the inlet and
secure the space.
2. Remove the obstacles of the outlet and
secure the space.
No
Has the outdoor unit been correctly installed?
No
Yes
Continued
30 seconds after power off, power on.
Re-install correctly under the product
specifications.
No
Yes
Poor installation
Pipe
Wire
ᐭ
ᐮ
ᐯ
Have the pipes and wires of indoor and
outdoor units been correctly installed?
Has the indoor unit been correctly installed?
[RC
6666
HXG
6
, RC
6666
HXH
6
, AC100FCA
6
GH:
Checking wire disconnection]
[RC072DHXB
6
: Checking wire disconnection]
[RC090/100/125/140
6
HXE
6
, RC100DHXB
6
,
AC
666
FCA
6