Troubleshooting
Samsung Electronics
4-27
Option
SEG1
SEG2
SEG3
SEG4
SEG5
Function
Page
Mode
Reserved
Use of external room temperature sensor / Minimizing fan
operation when thermostat is off
1)
Central control
Indication
and
details
Indication
Details
Indication
Details
Indication
Details
Indication
Details
0
2
Use of external room
temperature sensor
Minimizing fan operation
when thermostat is off
0
Disuse
0
Disuse
Disuse
1
Use
Disuse
2
Disuse
Use(Heating)
3
Use
Use(Heating)
4
Disuse
Use(Cooling)
5
Use
Use(Cooling)
1
Use
6
Disuse
Use (Cooling/Heating)
7
Use
Use (Cooling/Heating)
8
Disuse
Use (Cooling Ultra low
speed)
9
Use
Use (Cooling Ultra low
speed)
A
Disuse
Use (Heating/Cooling
Ultra low speed)
B
Use
Use (Heating/Cooling
Ultra low speed)
■ MPAH : AC***BNZDCH
• The installation options of indoor units are set to 020010-100000-200000-300000 by default.
Option No. for an indoor unit : 02XXXX-1XXXXX-2XXXXX-3XXXXX
Содержание AC009BN1DCH
Страница 187: ...Disassembly and Reassembly 3 134 Samsung Electronics No Parts Procedure Remark 7 Cabinet Front LF ...
Страница 291: ...PCB Diagram and Parts List Samsung Electronics 5 13 RAC AC018 024BNADCH 1 2 3 11 4 5 12 7 6 10 9 8 ...
Страница 293: ...PCB Diagram and Parts List Samsung Electronics 5 15 RAC AC030 036BNTDCH ...
Страница 305: ...PCB Diagram and Parts List Samsung Electronics 5 27 5 4 Outdoor Unit Main PBA PF2 3 AC009 012 018BXADCH AC018 024BXSCCC ...
Страница 307: ...PCB Diagram and Parts List Samsung Electronics 5 29 PF4 5 AC024 030 036 042 048BXADCH AC030 036BXSCCC AC030 036BXSCCH ...