20
English
P
ow
er Smar
t F
eat
ur
es
Setting the Off timer
When the air conditioner is turned on
1. Press the
Timer
button to select (Off).
- (Off) indicator will keep blinking and you can set the time.
2. Press the
<
or
>
button to set the time.
- You can set the time in half hour unit from 30 minutes (0.5 on
the display) ~ 3 hours and hour unit from 3 ~ 24 hours.
- Time can be set from minimum 30 minutes to maximum 24
hours.
3. Press the
SET
button to complete the Off timer setting.
- (Off) indicator and the set time of the timer will be displayed
on the remote controller display.
- Off timer setting will be cancelled if you don't press the
SET
button within 10 seconds after setting the time. Therefore,
check for the (Off) indicator on the remote controller display.
Cancel
Press the
Timer
button
select (Off)
press the
<
or
>
button
set the timer to
press the
SET
button.
•
Only the latest setting timer will be applied between the
Off Timer and good’ sleep off timer functions.
NOTE
Combining On timer and Off timer
When the air conditioner is turned off
When the air conditioner is turned on
When set time on On timer is shorter than Off timer
e.g.
On timer: 3 hours, Off timer: 5 hours
• The air conditioner will be turned on after 3 hours
from the moment you have set the timer and the
air conditioner will remain on for 2 hours and then
be turned off automatically.
When set time on On timer is longer than Off timer
e.g.
On timer: 3 hours, Off timer: 1 hour
• The air conditioner will be turned off after 1 hour
from the moment you have set the timer and will
be turned on after 2 hours from the moment it was
turned off.
• Set time for the On timer and the Off timer should be different from each other.
• When the On timer or the Off timer is set, setting can be cancelled by pressing the
Power
button.
NOTE
Remote controller display
Setting the On/Off timer