15
English
Installation Pr
oc
edur
e
• When installing insulation in the places and
conditions below, use the same insulation that is
used for high humidity conditions.
<Geological condition>
High humidity locations such as shorelines, hot springs, lake or
riversides, and ridges (when part of the building is covered by
earth and sand)
<Operation purpose condition>
Restaurant ceiling, sauna, swimming pool etc.
<Building construction condition>
Ceilings frequently exposed to moisture and cooling are
not covered. For example, pipes installed at a corridor of a
dormitory and studio or near an exit that opens and closes
frequently.
Places (where the pipes are installed) that are highly humid
due to a lack of ventilation.
Step 10 Installing the drain hose and
drain pipe
1
Push the supplied drain hose as far as possible over
the drain socket.
2
Tighten the metal clamp as shown in the picture.
3
Wrap the supplied large sealing pad over the metal
clamp and drain hose to insulate and fix it with clamps.
4
Insulate the complete drain piping inside the building
(field supply).
If the drain hose cannot be sufficiently set on a slope,
fit the hose with drain raising piping (field supply).
5
Push the drain hose up to insulation when connecting
the drain hose to drain socket.
Steel ring of drain hose
Joint of drain hose
Drain hose
Fix with Cable-Tie
Drain hose
Reducer
Wrap thermal sleeve hose
Indoor unit
A
A
A-A'
As shown in the figure,
tighten clamp of the drain
hose.
CAUTION
Check that the indoor unit is level with the ceiling by
using the leveller.
• Install air ventilation to drain condensation smoothly.
Air ventilation
Ceiling
• If it is necessary to increase the height of the drain
pipe, install the drain pipe straight within 12 inch
(300 mm) from the drain hose port. If it is raised
higher than 22 inch (550 mm), there may be water
leaks.
12 inch
(300 mm) or less
3/4 inch (20 mm)
or more
12
to
22 inch
(3
00
to
550 mm
)
Drain hose
Band joint
Ceiling
ki]_TXXY^ZhTWWptjhjG|GZ]WhhluUGGGX\