Deciding on Where to Install the Air Conditioner

E-

4

When deciding on the location of the air conditioner with the owner, the following restrictions
must be taken into account.

General

Do NOT install the air conditioner in a location where it will come into contact with the following elements:

Combustible gases

Saline air

Machine oil

Sulphide gas

Special environmental conditions

If you must install the unit in such conditions, first consult your dealer.

Indoor Unit

There must be no obstacles near the air inlet and outlet.

Install the indoor unit on a surface that can support its weight.

Choose a position that enables the piping and cables to be easily connected to the outdoor unit and the
recommended length of 5 metres to be respected.

Leave enough clearance beneath the indoor unit to enable the filters to be removed without hindrance.

Maintain sufficient clearance around the indoor unit, as indicated in the diagram on the page opposite.

Make sure that the water dripping from the drain hose runs away correctly and safely.

Outdoor Unit

The outdoor unit must NEVER be placed on its side or upside down, as the compressor lubrication oil will run into the
cooling circuit and seriously damage the unit.

Choose a location that is dry and sunny, but not exposed to direct sunlight or strong winds.

Do not block any passageways or thoroughfares.

Choose a location where the noise of the air conditioner when running and the discharged air do not disturb any
neighbours.

Choose a position that enables the piping and cables to be easily connected to the indoor unit and the recommended
length of 5 metres to be respected.

Install the outdoor unit on a flat, stable surface that can support its weight and does not generate any unnecessary
noise and vibration.

Position the outdoor unit so that the air flow is directed towards the outside, as indicated by the arrows on the top of
the unit.

Maintain sufficient clearance around the outdoor unit, as indicated in the diagram on the page opposite.

If the outdoor unit is installed at a height, ensure that its base is firmly fixed in position; the maximum height(“H”:
indicated in the diagram on the page opposite.) is 7 metres.

Make sure that the water dripping from the drain hose runs away correctly and safely.

◆  

You have just purchased a split-type room air conditioner and it has 

been installed by your installation specialist.

This device must be installed according to the national electrical rules.

C

C

C

C

A

A

A

A

U

U

U

U

T

T

T

T

II

II

O

O

O

O

N

N

N

N

P

REPARING THE

I

NSTALLATION

Содержание 12A1VB

Страница 1: ...lte raumklimaanlage Kühlen und Wärmen ENGLISH ESPAÑOL ITALIANO PORTUGUÉS FRANÇAIS DEUTSCH E S I P F D DB68 00217A 8 ASH070VE D ASH090VE D ASH120VE D ASH071VE D ASH091VE D ASH121VE D ASH074VE D ASH094VE D ASH124VE D ASH075VE D ASH095VE D ASH125VE D Indoor Unit Outdoor Unit AXH070VE D AXH090VE D AXH120VE D AXH071VE D AXH091VE D AXH121VE D AXH074VE D AXH094VE D AXH124VE D AXH075VE D AXH095VE D AXH125...

Страница 2: ...E 2 ...

Страница 3: ...r Unit Assembly Piping 10 Cutting Extending the Piping 11 INSTALLING THE OUTDOOR UNIT Connecting the Cables to the Outdoor Unit 12 Checking Correct Earthing 13 Installing and Connecting the Outdoor Unit Drain Hose 14 Fixing the Unit in Position 14 COMPLETING THE INSTALLATION Connecting Up and Purging the Circuit 15 Performing Leak Tests 16 Placing the Indoor Unit in Position 16 Checking and Testin...

Страница 4: ... the cooling circuit and seriously damage the unit Choose a location that is dry and sunny but not exposed to direct sunlight or strong winds Do not block any passageways or thoroughfares Choose a location where the noise of the air conditioner when running and the discharged air do not disturb any neighbours Choose a position that enables the piping and cables to be easily connected to the indoor...

Страница 5: ...espect the clearances and maximum lengths indicated in the diagram below when installing the unit 125 mm or more 600 mm minimum 300 mm minimum 300 mm minimum 600 mm minimum L metres maximum H metres maximum ENGLISH PREPARING THE INSTALLATION Model 07 09 12 Model 07 09 12 H 7 7 7 L 10 10 15 ...

Страница 6: ...le above 1 0mm2 area or approved according to IEC standard The flare nuts drain plug drain cap A B and rubber leg are only included when the air conditioner is supplied without the assembly piping illustrated below The following connection accessories may be supplied depending on the option If they are not supplied it is recommended that you collect them together before starting to install the air...

Страница 7: ... mm so that it slants slightly downwards 2 If you are fixing the indoor unit to a Then follow Steps Wall 3 Window frame 4 to 6 3 Fix the installation plate to the wall in a manner appropriate to the weight of the indoor unit If you are mounting the plate on a concrete wall with anchor bolts the anchor bolts must not project by more than 20 mm 4 Determine the positions of the wooden uprights to be ...

Страница 8: ...t first be extended to a maximum of 10 15 metres 1 Extend the assembly cable if necessary 2 Open the front grille by pulling on the tabs on the lower right and left sides of the indoor unit 3 Remove the screw securing the connector cover 4 Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals Each wire is labelled with the corresponding terminal nu...

Страница 9: ...ted for gas leaks refer to page 16 for further details Installing and Connecting the Indoor Unit Drain Hose E 9 Care must be taken when installing the drain hose for the indoor unit to ensure that any condensation water is correctly drained outside When passing the drain hose through the 65 mm hole drilled in the wall check that none of the following situations occur The hose must NOT slope upward...

Страница 10: ...ing the nuts first manually and then with a wrench applying the following torque Pipe Outer Diameter Torque kg cm Liquid refrigerant 6 35 mm 160 Gas refrigerant 9 52 mm 300 Gas refrigerant 12 70 mm 500 If the piping must be shortened or extended refer to page 11 4 Cut off any excess foam insulation 5 If necessary bend the pipe round along the bottom of the indoor unit and out through the appropria...

Страница 11: ...ctly Oblique Rough Burr 3 To prevent any gas from leaking out remove all burrs at the cut end of the pipe using a reamer 4 Slide a flare nut on to the pipe and modify the flare Pipe Outer Diameter D Depth A Liquid refrigerant 6 35 mm 1 3 mm Gas refrigerant 9 52 mm 1 8 mm Gas refrigerant 12 70 mm 2 0 mm 5 Check that the flaring is correct referring to the illustrations below for examples of incorre...

Страница 12: ...esponding terminal number 3 Connect the earth wires to the earth terminals Refer to the page opposite for further details on how to check that earthing is correct 4 Replace the terminal board cover carefully tightening the screw 5 Connect the power cable with the indoor unit E 12 1 N 2 3 4 5 A B C D 1 5 4 3 2 A B C D E Indoor unit Outdoor unit Earth terminal INSTALLING THE OUTDOOR UNIT SH YAA B SH...

Страница 13: ...e size indicated in the illustration opposite drive the earth ing electrode into position and cover the top of the electrode with the exca vated soil 4 Install a green yellow insulated earthing wire Ø1 6 mm section 2 mm2 or greater If the earthing wire is too short connect an extension lead soldering the connection and wrapping it with insulating tape do not bury the soldered connection Secure the...

Страница 14: ... any increase in the noise level and vibration particularly if the outdoor unit is to be installed close to a neighbour If it is to be installed in a location exposed to strong winds or at a height the unit must be fixed to an appropriate support wall or ground 1 Position the outdoor unit so that the air flow is directed towards the out side as indicated by the arrows on the top of the unit 2 Atta...

Страница 15: ...rigerant 19 52 mm 3 8 300 Gas refrigerant 12 70 mm 1 2 500 3 Connect the charging hose of low pressure side of manifold gauge to the packed valve having a service port as shown at the figure 4 Open the valve of the low pressure side of manifold gauge counter clockwise 5 Purge the air from the system using vacuum pump for about 10 minutes Close the valve of the low pressure side of manifold gauge c...

Страница 16: ...late 1 To avoid condensation problems place heat resistant polyethylene foam sep arately around each refrigerant pipe in the lower part of the indoor unit 2 Wind insulating tape around the pipes assembly cable and drain hose 3 Place the resulting bundle carefully in the lower part of the indoor unit mak ing sure that it does not jut out from the rear of the indoor unit 4 Hook the indoor unit on to...

Страница 17: ... leakages Connection wiring Heat resistant insulation of the piping Drainage Earthing wire connection Correct operations follow the steps below 2 Press the On Off button Result The indicator lights on the indoor unit flash at half second intervals While the indoor unit opens the indoor unit fan runs to start 3 Press the button Result The outdoor unit operates in cooling or heating mode as followin...

Страница 18: ... the owner making reference to the appropriate pages in the owner s instruction booklet 1 How to start and stop the air conditioner 2 How to select the operating mode and adjust the temperature and fan set tings 3 How to adjust the air flow direction 4 How to set the timers 5 How to remove and clean the filters Once the owner is happy with the basic operations hand over the owner s instruc tion bo...

Страница 19: ...VE 094VE 124VE ASH075VE 095VE 125VE AQ07A1 A2 VE 09A1 A2 VE 12A1 A2 VE SH07YA0 SH09YA0 SH12YA0 SH09ZV 12ZV SH07YAA B SH09YAA B SH12YAA B Model Indoor unit ASH070VD 090VD 120VD ASH071VD 091VD 121VD ASH074VD 094VD 124VD ASH075VD 095VD 125VD AQ09A1 A2 VB 12A1 A2 VB 220 240V 50Hz 200 220V 50Hz 220V 60Hz Power Supply ...

Страница 20: ...ANUFACTURED BY ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR QUESTO CONDIZIONATORE D ARIA È PRODOTTO DA ESTE APARELHO DE AR CONDICIONADO É FABRICADO POR CE CLIMATISEUR EST FABRIQUE PAR DIESE KLIMAANLAGE IST FABRIZIERT VON Printed in Korea ...

Отзывы: