background image

                                                      

2016 b fast connect 

1

 

 
 

 
 
 

 

 
 
 

 

 
 

 

 
 
 
 
 
 
 
 
 

 
 
 

 with 
 

 

 
 
 
 

 
 

Scan this code to go directly to our YouTube channel  

 
 

 

 

Air Source Heat Pump 

Installation and Maintenance Manual 

 

Model Numbers: 

MIM-E03 A and B N 

AE 050-090-120-140-160JXYDEH 

 
 

Содержание 050JXYDEH

Страница 1: ...2016 b fast connect 1 with Scan this code to go directly to our YouTube channel Air Source Heat Pump Installation and Maintenance Manual Model Numbers MIM E03 A and B N AE 050 090 120 140 160JXYDEH ...

Страница 2: ...e bolts The unit must have adequate drainage away from the unit it can produce up to 6 L hour If you are installing the unit at height you can install a drain pan under the unit but its best to let the unit drain into the ground Dimensions Size 16 1420mm h 940mm w 330mm d 103kg Size 9 998mm h 940mm w 330mm d 75kg Size 5 798mm h 880mm w 310mm d 59kg The space around the unit is very important allow...

Страница 3: ...m 0 3Bar pressure Diverter valves If you require multiple heating zones you need to supply a 2 port diverter valves per zone Glycol anti freeze In Monobloc heat pumps the water goes outside the building The unit can protect itself from freezing up but if the power goes off there is a risk that the unit will freeze causing damage To prevent this we recommend putting propylene glycol mixture in the ...

Страница 4: ...The fast connection kit comes with all the accessories you need except a robokit and Cylinder The idea is the fast connect kit goes on the wall inside and is pre wired and commissioned The plumber connects the cylinder the heat pump and the heating circuit ...

Страница 5: ... It is possible to connect this system to solar PV powered immersion heaters I boost Immersun etc Heating is controlled using a wall mounted thermostat time clock field supplied There are no limits to the number of heating zones which can be connected to this system This system shows 2 heating zones Pump 2 and Pump 3 Each zone has its own thermostat timer which drives a dedicated zone valve The zo...

Страница 6: ...zone heating page 3 of 4 The sparky connects the tank thermostat sensor 15m long can t be extended The immersion heater to the cylinder the thermostat or run signal input The 2 core F1F2 cable to the outdoor unit its 10m long and a power supply 16 Amps ...

Страница 7: ... heating zones page 3 of 4 The sparky connects the tank thermostat sensor 15m long can t be extended The immersion heater to the cylinder the thermostat or run signal input The 2 core F1F2 cable to the outdoor unit its 10m long and a power supply 16 Amps ...

Страница 8: ... kit The fast connect board goes outside it s in a waterproof enclosure 600 high x 800 wide x 300mm deep The fast connection kit has energy meters installed so the installer needs no other parts Just T into the heating circuit and modify the wiring as above ...

Страница 9: ...ect the stat from the boiler and wire it to the fast connect Run a cable from fast connect to the boiler Connect a single power supply to the fast connect board Run a supply from fast connect to the heat pump outdoor unit Connect the pre wired comms cable to the outdoor unit ...

Страница 10: ...r will be dead for about a minute after that it will come to life You will see 00 or 01 on the remote controller screen for 90 seconds If 01 continues to show the outdoor unit is not powered up Setting the Clock and Backlight 1 Press User Set once 1 shows on the screen 2 Press up until 2 shows 3 Press right twice Year will show use up to change year Press Set 22 appears 4 Press right Month will be...

Страница 11: ...left of the screen adjust it with the up and down buttons to store this value press Set 4 Press left to go back to 2011 press up to the next field setting and repeat 5 When you have finished all your 20 settings press left twice 20 will show on the screen press the up button to move to the 30s and repeat the procedure from 2 above When finished or if you get lost press ESC to return to the normal ...

Страница 12: ...nstantly in test mode When the pump is running you can see a picture of a house with a circle round it With all your stats off the controller will display the word TEST When you send any run signal to the unit it will change to HEAT1 Turn up a stat or the underfloor heating to test this Now if you turn the stats and the UFH off TEST will show again If you are doing a Hybrid system you can test the...

Страница 13: ...in on the 16kW unit If there is not enough flow the unit will never operate If you look into the flow meter you can see the flow in litres per minute The flow rate is the low figure in this picture you can see a flow rate indicated this shows 25l min NOT 35l min If the flow rate is too low you need to fix this before moving on Turn up your pumps remove any air and if it s still not enough you need...

Страница 14: ...ure at the remote controller which is not used The house with the circle around it is the water outlet temperature from the heat pump The Christmas tree is the air temperature outside The tap is the cylinder temperature The flow temperature is shown next to a symbol of a house in a circle Over time this will warm up now check all the radiators or under floor loops are hot as well If the outdoor un...

Страница 15: ...ns that the unit measures the outside temperature and adjusts the radiator temperature to suit The colder it is outside the warmer the rads will be and vice versa This function is automatic and is designed to save you money In very cold weather the radiator will be at their hottest they will reach 50C Once the temperature outside gets cold your heat pump will stop and it will fire the boiler this ...

Страница 16: ...E for example E911 A00 Normally there is a sun symbol at the top of the screen if the unit is faulting the sun disappears The engineer will want to know this number when you call Please avoid turning the unit off at the power supply especially in cold weather If the unit is off and the weather is very cold it cannot protect itself If the unit is off and the temperature outside is cold it will auto...

Страница 17: ...mpany only this is NOT an end user warranty It is the role of the installer to offer a warranty to the end user covering all of the heating system including the heat pump The standard warranty is valid for 12 months from date of delivery as entered on this card If the unit is installed by a Samsung approved installer and this card is sent back within 30 days of delivery date the warranty is automa...

Страница 18: ...2016 b fast connect 18 I accept the terms of the Samsung warranty and confirm the system has been registered within 30 days of delivery I also include a copy of the delivery note Signed Name ...

Страница 19: ... bar We need to test the operation of the unit against the hot water cylinder So first we need to draw off 50 liters of water run a couple of taps for 5 mins to achieve this The unit should start up automatically in hot water mode if it doesn t press the DHW power button on the controller in 3 4 mins it will start heating the cylinder a coke can symbol will show in the status section of the remote...