| DOC9091B
13
Truck Master 1700
Together with the air there will be a water flow out of the pump up to 6 m3/h.
The water will be separated from the air in the liquid separator.
Depending of the size of particles, water will be carried with the water when the air velocity is more than
3-4 m/s.
The inlet speed to the separator can be more than 50 m/s and this must be reduced to 3 m/s.
Below you find an illustration showing how to reduce the speed and control that no water will be in contact
with the high velocity air stream. The round velocity reducer can be placed inside any tank geometry.
3.1 Function and design of a liquid separator
DOC1627391
Air flow [m³/h]
øD minimum [mm]
1700
450
1600
430
1500
420
1400
410
1300
390
1200
375
øD so the velocity is below 3 m/s
H=4 to 6*d depending on the geometry. A smooth diameter conversion will give a low factor.
Содержание TRUCK MASTER 1700
Страница 33: ...DOC9091B 33 Truck Master 1700 Notes...
Страница 34: ...DOC9091B 34 Truck Master 1700 Notes...
Страница 35: ...DOC9091B 35 Truck Master 1700 Notes...