1:  Audio on-off switch

 - When set to the “on” 

position, audio signal is transmitted.  When set to 

the “off” position, the audio signal is muted.  Because 

the carrier signal remains during muting, no “pop” or 

“thud” will be heard.  Note that turning this off does 

not 

turn off the transmitter power—it is simply a 

way to temporarily mute the transmission of audio 

signal.  If you don’t plan on using the HT5 for extended 

periods, turn off its power by using the power on-off 

switch (see #3 below).

2:  Battery level meter

 - This set of three  multicolor 

LEDs indicates relative battery power, indicating 

whether the installed battery is at low (red), mid 

(yellow) or high (green) strength. One or more of 

these will light whenever the HT5 is powered on (see 

#3 below).  When all three are lit, the battery is at 

maximum strength.  When only the red “low” indicator 

lights, RF performance is degraded and the battery 

needs to be replaced.

3:  Power on-off switch*

 - Use this to turn the HT5 on 

or off (to conserve battery power, be sure to leave it off 

when not in use).

4:  Gain control (trimpot)

 - This input sensitivity 

control has been factory preset to provide optimum 

level for the particular microphone capsule provided with your Stage 5 Series system and so we 

recommend that this not be adjusted manually.  If necessary, however, you can use the supplied 

plastic screwdriver to raise or lower the input level.  See the “Setting Up and Using Your Stage 

5 Series System” section on page 5 in this manual for more information.

5:  Battery holder

 - Insert a standard 9-volt alkaline battery here, being sure to observe the 

plus and minus polarity markings shown.  We recommend the Duracell MN 1604 type battery.  

Although rechargeable Ni-Cad batteries can be used, they do not supply  adequate current for 

more than four hours. 

WARNING:

  Do not insert the battery  backwards; doing so can cause severe 

damage to the HT5 and will void your warranty.

* Be sure to mute the audio signal at your external mixer or amplifier before turning  transmitter power 

on or off, or an audible pop may result.

Содержание STAGE 5H

Страница 1: ......

Страница 2: ...45 Gilpin Avenue Hauppauge New York 11788 8816 Phone 1 800 3 SAMSON 1 800 372 6766 Fax 631 784 2201 www samsontech com Table of Contents Introduction 1 Guided Tour SR5 Front Panel 2 Guided Tour SR5 Rear Panel 3 Guided Tour HT5 4 Setting Up and Using Your Stage 5 Series System 5 6 Specifications 8 ...

Страница 3: ...es of your Stage 5 Series system as well as a guided tour through all components step by step instructions for setting up and using your system and full specifications If your Stage 5 Series system was purchased in the United States you ll also find a warranty card enclosed don t forget to fill it out and mail it This will enable you to receive online technical support and will allow us to send yo...

Страница 4: ...gth If no segments are lit little or no signal is being received See the Setting Up and Using Your Stage 5 Series System section on page 5 in this manual for more information 4 Squelch control This control determines the maximum range of the SR5 before audio signal dropout Although it can be adjusted using the supplied plastic screwdriver it should normally be left at its factory setting See the S...

Страница 5: ...and Pin 3 low cold 3 Audio Output Level switch Sets the audio output level attenuation of the balanced output see 2 above to 20 dBm line level or 40 dBm mic level See the Setting Up and Using Your Stage 5 Series System section on page 5 in this manual for more information 4 Unbalanced output Use this unbalanced high impedance 5K Ohm 1 4 jack when connecting the SR5 to consumer 10 audio equipment W...

Страница 6: ...r on off switch Use this to turn the HT5 on or off to conserve battery power be sure to leave it off when not in use 4 Gain control trimpot This input sensitivity control has been factory preset to provide optimum level for the particular microphone capsule provided with your Stage 5 Series system and so we recommend that this not be adjusted manually If necessary however you can use the supplied ...

Страница 7: ...t the supplied AC adapter to the DC Input on the rear panel of the SR5 then plug the adapter into any standard AC outlet Press the front panel Power switch to turn on the SR5 the green Power LED will light up but all other front panel LEDs will remain unlit 8 Turn on the power to the HT5 transmitter using its Power on off switch all three Battery strength LEDs will light if the battery is sufficie...

Страница 8: ...y silent if it is skip ahead to the next step If it isn t that is if you hear some noise you may need to adjust the receiver s front panel Squelch control When the Squelch control is at its minimum setting the Stage 5 Series system always provides maximum range without dropout however depending upon the particular environment your system is used in you may need to reduce that range somewhat in ord...

Страница 9: ...tem Single conversion Superheterodyne Frequency Range 173 80 MHz to 213 20 MHz 25 frequencies Band A European UK models 160 10 to 177 90 MHz Band B European UK models 189 10 to 210 10 MHz Receiving Mode 80KF3E Sensitivity 3 µV for 20 dB SINAD 10 µV for 50 dB S N Selectivity 120 kHz BW nominal 6 dB 300 kHz adj CH 75 dB Squelch Sensitivity 3 µV to 250 µV adjustable Intermediate Frequency 10 7 MHz Lo...

Страница 10: ...l requirements and other relevant requirements of the R TTE Directive 1999 5 EC SAMSON TECHNOLOGIES CORPORATION 575 Underhill Boulevard Syosset New York 11791 USA Applicable Standards Title EN 60065 2002 Audio video and similar electronic apparatus Safety requirements EN 301489 9 v1 2 1 2000 08 Electromagnetic compatability and Radio spectrum Matters ERM Part 9 Specific conditions for wireless mic...

Страница 11: ...ce Canada Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received includ ing interference that may cause undesired operation 4UBHF 8JSFMFTT JDSPQIPOF 4ZTUFNT PVOUSZ PEF PEF EF 1BZT BFOEFS VF FM SFRVFODZ 3BOHF BOEF EF SÏRVFODFT VUPSJTÏF SFRVFO CFSFJDI 4 5 64 o 3 MM PUIFS DPVOUSJFT 1MFBTF DPOUBDU ZP...

Страница 12: ...Samson Technologies Corp 45 Gilpin Avenue Hauppauge New York 11788 8816 Phone 1 800 3 SAMSON 1 800 372 6766 Fax 631 784 2201 www samsontech com Stage5H_om_ v1 ...

Отзывы: