background image

Safety Instructions

Important Safety Instructions

1.  Please read all instructions before operating the unit. 

2.  Keep these instructions for future reference. 

3.  Please heed all safety warnings. 

4.  Follow manufacturers instructions.   

5.

Do not use this unit near water or moisture. 

6.  Clean only with a damp cloth.  

7.

Do not block any of the ventilation openings. Install in accordance with the manufacturers instructions. 

8.  Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including 

amplifiers) that produce heat.  

9.  Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with 

one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or 
third prong is provided for your safety. When the provided plug does not fit your outlet, consult an electrician for 
replacement of the obsolete outlet.  

10.  Protect the power cord from being walked on and pinched particularly at plugs, convenience receptacles and at 

the point at which they exit from the unit.  

11.  Unplug this unit during lightning storms or when unused for long periods of time.  

12. Refer all servicing to qualified personnel. Servicing is required when the unit has been damaged in any way, 

such as power supply cord or plug damage, or if liquid has been spilled or objects have fallen into the unit, the 
unit has been exposed to rain or moisture, does not operate normally, or has been dropped.

Caution:

To reduce the hazard of electrical shock, do not

remove cover or back. 

No user serviceable parts inside. Please refer all servic-
ing to qualified personnel. 

WARNING

: To reduce the risk of fire or electric shock, do not expose this unit to rain or moisture. 

The lightning flash with an arrowhead symbol within an equilateral triangle, is intended to alert the user to the
presence of uninsulated "dangerous voltage" within the products enclosure that may be of sufficient magnitude
to constitute a risk of electric shock to persons.  

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the literature accompanying the product.  

Содержание S-curve 215

Страница 1: ...6 3K 10K 16K 25 40 63 100 160 250 400 630 1K 1 6K 2 5K 4K 6 3K 10K 16K 25 40 63 100 160 250 400 630 1K 1 6K 2 5K 4K 6 3K 10K 16K 25 40 63 100 160 250 400 630 1K 1 6K 2 5K 4K 6 3K 10K 16K CH 2 LOW CUT...

Страница 2: ...venience receptacles and at the point at which they exit from the unit 11 Unplug this unit during lightning storms or when unused for long periods of time 12 Refer all servicing to qualified personnel...

Страница 3: ...es 12 Using a Patchbay 12 Using the S curve 215 with an RTA 13 Using the S curve 215 to Ring Out a Monitor System 14 S curve 215 Wiring Guide 15 Specifications 16 Pass Band Graphs 16 Block Diagram 17...

Страница 4: ...guided tour through the front and rear panels step by step instructions for using the unit suggested applications for use with a patch bay a Real Time Analyzer RTA or for ringing out monitor systems...

Страница 5: ...elay controlled Bypass switches with dedicated Bypass LEDs allow the equalization circuitry and output level control to be activated or deactivated Level controls enable output signals to be attenuate...

Страница 6: ...the 6 dB position the corresponding output signal is boosted by 6 dB When a Level slider is moved all the way down to the position the corresponding output signal is infinitely attenuated that is the...

Страница 7: ...ack output Electronically balanced XLR jack output Wiring is as fol lows pin 2 hot pin 3 cold and pin 1 ground D Balanced 1 4 TRS jack input Electronically balanced 1 4 TRS jack input Wiring is as fol...

Страница 8: ...0 400 630 1K 1 6K 2 5K 4K 6 3K 10K 16K CH 2 LOW CUT CH 2 0 6 3 20 OFF BYPASS CH 1 LOW CUT CH 1 30 18 6 0 18 6 30 18 6 0 18 6 4 The S curve 215 can be used either as an in line device as an insert devi...

Страница 9: ...olume of the output signal so that they do not light at all clipping not only sounds awful it can also damage speakers 9 Experiment by moving each of the Equalizer sliders up and down carefully listen...

Страница 10: ...el 2 outputs are connected to the inputs of the active self powered loudspeakers Using the S curve 215 with Passive Speakers In this example the mixer s left and right outputs are connected to the S c...

Страница 11: ...S Curve 215 Wiring Guide page 15 in this manual In this example the S curve 215 is used for both the main PA speakers running a mono mix and for the monitor mix also in mono For the main PA the mixer...

Страница 12: ...main PA speakers Then the first S curves 215 s Channel 1 and Channel 2 outputs are connected to the inputs of the power amplifier for the main speakers For the monitor mix the mixer s AUX1 and AUX2 ou...

Страница 13: ...same range by cutting EQ notches in a loud signal you can actually make room for a softer one to shine through And try not to think of EQ as a miracle worker no amount of equalization can put a singe...

Страница 14: ...rence by planning your audio electrical and computer cable runs so that they are as far apart from one another as possible and so they don t run parallel to one another If they have to cross try to en...

Страница 15: ...se consists of all audible fre quencies blended together at equal level the RTA should in theory show all frequency bands to be flat However due to anomalies in every physical environment this will ra...

Страница 16: ...for typical configuration diagrams Next power up all audio equipment turning on the amplifiers last and using one monitor output only gradually turn up the volume while a performer is speaking or sing...

Страница 17: ...2 1 3 Tip signal Signal tip Signal ring Signal tip Signal ring Ring signal Sleeve ground Ground Ground Tip signal Signal tip Signal ring Signal tip Signal ring Ring signal Sleeve ground Ground Ground...

Страница 18: ...nity 10 Hz to 90 kHz 3 dB THD N unity gain Less than 0 01 20Hz to 20kHz Max Output Level gain 6 dB High pass filter 80 Hz 18 dB oct Noise with 20 kHz LPF all faders flat 85 dB Dimensions 19 in w x 10...

Страница 19: ...17 S curve 215 Block Diagram...

Страница 20: ...Samson Technologies Corp 575 Underhill Blvd P O Box 9031 Syosset NY 11791 9031 Phone 1 800 3 SAMSON 1 800 372 6766 Fax 516 364 3888 www samsontech com...