Specifications 

Type:  

Condenser 

Polar Pattern:  

 Cardioid/Figure 8 
Omni

Frequency Response:  

20~20 kHz

Sensitivity:  

Cardioid 

-37 dBV/Pa

 

Figure 8 

-40 dBV/Pa

 

Omni 

-40 dBV/Pa

Rated Impedance: 

200 Ohms

Minimum Load Impedance:  

1000 Ohms

Equivalent Noise Level: 

 

Cardioid 

16 dB

Figure 8

19 dB

 

Omni 

19 dB

CL8 Specifications

CL8 Specifications

Max. SPL:  
 

Cardioid 

144 dB

Figure 8

147 dB

 

Omni 

147 dB

Signal-to-Noise Ratio:  

Cardioid 

78 dB

Figure 8

75 dB

 

Omni 

75 dB

Dynamic Range:  

128 dB

Power Supply:   

48V +/-3 dB

Current Consumption: 

 4mA

Specifications subject to change without notice.

Cardioid Frequency Response Graph

Cardioid

Cardioid

Cardioid Polar Pattern

Figure 8  Frequency Response Graph

Figure 8 Polar Pattern

Omni Frequency Response Graph

Omni Polar Pattern

ni

ni

CL8_ownman.indd   8

10/12/04   8:26:28 PM

Содержание CL8

Страница 1: ...Multi Pattern Large Diaphragm Condenser Microphone P R O F E S S I O N A L M I C R O P H O N E S CL8 CL8_ownman indd 1 10 12 04 8 26 13 PM...

Страница 2: ...gure 8 5 Microphone Placement 6 P Popping 6 Stand Mounting 6 Using the Optional SP01 Spider Shock Mount 7 Specifications 8 K TEAM A PRODUCTION Copyright 2004 Samson Technologies Corp Printed October 2...

Страница 3: ...mation about these and other Samson products in the future With proper care and adequate air circulation your CL8 will operate trouble free for many years We recommend you record your serial number in...

Страница 4: ...ble without lighting the PEAK LED If you try turning the Gain control all the way down and the PEAK light is still lighting try using the CL8 s PAD as explained in the following section Using the PAD...

Страница 5: ...The Omni mode is also great for recording ensemble performances from groups of vocals brass woodwind and other instruments with the artists facing each other in a circle around the microphone As an ad...

Страница 6: ...que in capturing the optimum sound of drum set acoustic guitar piano or other instruments in a live room or sound stage Experimentation and experience are the best teachers in getting good sounds so p...

Страница 7: ...Insert the internal shock mount washer into the SP01 with the curved side up Figure 1 Internal Shock mount Washer 3 Tighten the SP01 threaded collar nearly all the way then position the microphone and...

Страница 8: ...ise Level Cardioid 16 dB Figure 8 19 dB Omni 19 dB CL8 Specifications CL8 Specifications Max SPL Cardioid 144 dB Figure 8 147 dB Omni 147 dB Signal to Noise Ratio Cardioid 78 dB Figure 8 75 dB Omni 75...

Отзывы: