Fault
Potential cause
Solution
Valve leaks downstream
(doesn't close or doesn't
close fully)
Operating pressure too high
Operate valve with operating
pressure specified
in data sheet
Foreign matter between seat
seal* and seat
Remove bonnet, remove foreign
matter, check
seat seal for damage and replace if
necessary
Valve body leaky or damaged
Check valve body and replace if
necessary
Seat seal faulty
Check seat seal for damage and
replace if
necessary
Valve doesn't open or
doesn't open fully
Bonnet faulty
Replace bonnet
Medium escapes from the
valve spindle* (underneath
handwheel)
Gland packing faulty
Replace bonnet
Valve leaks between
bonnet and valve body
Bonnet loose
Retighten bonnet retaining nut
flat sealing faulty
Check gasket and the respective
sealing surfaces
for damage and replace parts if
necessary
Valve body / bonnet damaged
Replace valve body / bonnet
Valve body connection to
piping leaks
Incorrect installation
Check installation of valve body in
piping
Threaded connections / flange
bolting loose
Retighten threaded connections /
flange bolting
Sealing components faulty
Replace sealing components
Valve body leaks
Valve body leaks or is corroded
Check valve body for damage,
replace valve body
if necessary
Handwheel cannot be
turned
Bonnet faulty
Replace bonnet