Mounting the intermediate plate
1. Remove the fixing screws and lift the
supply pressure regulator (4) together
with the diverting gasket (3) off the
adapter plate (1).
Make sure you do not change the posi-
tion of the diverting gasket in the supply
pressure regulator.
Note:
The long rubber finger of the diverting
gasket (3) must always point in the direction
of the regulator outlet (reduced supply air).
See Figs. 10, 11 and 12.
2. Insert O-rings (2.1) in the holes of the in-
termediate plate (2).
3. Place the intermediate plate onto the
adapter plate in such a way that the
three holes located next to one another
are positioned over both 5 mm holes on
16
EB 8546 EN
Pneumatic connections
1
1.1
E
AM
A
2
2.1
3
4
4.1
A
A
E
A
E
A
E
Fig. 11 · Mounting an intermediate plate on Type 3372 Actuator
Output for
reduced supply air
Supply air input
Intermediate
plate (2)
Содержание 4708-1152
Страница 31: ...EB 8546 EN 31...