6

Guided Tour - Rear Panel

1:  AC input -  Connect the supplied standard 3-pin “IEC” plug here.

2:  Fuse holder - In the Servo Quad 4060, insert an 6 amp, 125 volt fuse here for 115 volt operation, or
a 3.15 amp, 250 volt fuse for 230 volt operation.  In the Servo Quad 4120, insert an 8 amp, 125 volt fuse
here for 115 volt operation, or a 6.3 amp, 250 volt fuse for 230 volt operation.  We recommend the use
of normal (as opposed to slow-blow) fuses.  WARNING: Fuses should only be replaced with the power
cord disconnected.

3:  Binding post (banana jack) output connectors (Ch 1 - 4) - Use these to connect each channel of
the Servo Quad Amplifier to loudspeakers.  Be sure to connect the loudspeaker correctly, with the red
(+) terminal normally connected to the positive input of the speaker and the black (-) terminal normally
connected to the negative input of the speaker.  See the “Bridge Stereo Mode” section on page 7 in this
manual for speaker connection instructions when using the Servo Quad Amplifier in bridge mode.

4:  Balanced Inputs* (Ch 1 - 4) - Connect incoming signal to these electronically balanced 1/4" TRS
(Tip/Ring/Sleeve) jacks, wired as follows: Tip hot, Ring cold, and Sleeve ground.  Use balanced three-
conductor cabling and TRS plugs wherever possible (unbalanced two-conductor plugs can also be
inserted into these inputs, but you’ll get better signal quality and less outside noise and hum if you
use balanced lines).  Note that the Servo Quad Amplifier balanced inputs are 6 dB higher in gain than
the balanced inputs (see #5 below).  The Servo Quad Amplifier accepts input levels of any strength but
needs at least 0 dBm to get maximum power.

5:  Unbalanced Inputs* (Ch 1 - 4) - Connect incoming signal to these unbalanced RCA-type jacks.
The Servo Quad Amplifier accepts input levels of any strength but needs at least 0 dBm to achieve
maximum power.  Note that the Servo Quad Amplifier unbalanced inputs are 6 dB lower in gain than the
balanced inputs (see #4 above).

6: Bridge switch - For normal operation, place this switch at its left (“OFF”) position.  When placed at its
right (“ON”) position, each of the two amplifier sections (channel 1 and channel 2 and/or channel 3 and
channel 4) are bridged, providing full 120 or 240 watt power output, depending upon the Servo Quad
model you’re using.  For more information, see the “Bridge Stereo Mode” section on page 7 in this
manual.  WARNING: Due to the extremely high power output of the Servo Quad Amplifier when used in
Bridge Stereo mode, be sure to use only 8 ohm loudspeakers sufficiently rated to handle the resultant
wattage.

* If required, both the balanced and unbalanced inputs can be used simultaneously.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

!

USE CLASS 2 WIRING

AVIS;

RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR

DO NOT EXPOSE THIS EQUIPMENT

TO RAIN OR MOISTURE.

emc

EUR . USA . JPN

BRIDGE

OFF

ON

CH4  R

CH3  R

CH4

CH3

4

 120W

MAX. LOAD

-

+

+

-

CH2  L

CH1  L

-

+

+

-

BRIDGE

OFF

ON

SAMSON

SERIAL NUMBER

SERVO 4120

QUAD AMPLIFIER

SAMSON TECHNOLOGIES CORP., U.S.A.

AC

INLET

USA & CANADA 115V - 60Hz

EUROPE & UK 230V - 50Hz

650W MAX.

CAUTION:

DISCONNECT SUPPLY CORD

BEFORE CHANGING FUSE.

FOR CONTINUED PROTECTION

AGAINST RISK OF FIRE, REPLACE

ONLY WITH SAME TYPE OF FUSE.

ATTENTION:

DEBRANCHER AVANT DE

REMPLACER LE FUSIBLE.

UTILISERUN FUSIBLE DE

RECHANGE DE MEM TYPE.

USA  &  CANADA

T 8A/125V (115V)

EUROPE AND UK

T 6.3A/250V (230V)

FUSE

2

3

1

3

4

4

6

6

-

+

+

-

MONO 8

-

+

CH2

CH1

4

 120W

MAX. LOAD

-

+

+

-

MONO 8

-

+

Содержание 4060/4120

Страница 1: ...OWNERS MANUAL Q U A D AMPLIFIER SERVO 4060 4120...

Страница 2: ...Panel 5 Rear Panel 6 Setting Up and Using the Servo Quad Amplifier 7 The Servo Quad Amplifier Protection Circuitry 8 Bridge Stereo Mode 9 Bi amplification Applications 10 Appendix A Linearity vs Freq...

Страница 3: ...lifier boasts professional specs which far exceed that of most consumer products For a real studio experience in your own home try connecting your home hi fi amplifier s auxiliary outputs to the Servo...

Страница 4: ...jacks are provided Binding post banana jack output connectors Convection cooling no fan makes for whisper quiet operation even in critical listening environments such as recording studios Unique bipo...

Страница 5: ...hould light occasionally during peak levels if it lights frequently you may be overloading the Servo Quad Amplifier and a distorted clipped signal is probably being output If this occurs and backing o...

Страница 6: ...eds at least 0 dBm to get maximum power 5 Unbalanced Inputs Ch 1 4 Connect incoming signal to these unbalanced RCA type jacks The Servo Quad Amplifier accepts input levels of any strength but needs at...

Страница 7: ...ou use balanced lines If you are using the Servo Quad Amplifier for bi amping applica tions refer to the Bi amplification Applications section on page 8 in this manual 5 On the front panel of the Serv...

Страница 8: ...adequate ventilation on all sides see page 5 for more information in extreme environmental conditions you may also want to consider the use of cooling fans Severe overcurrent conditions This occurs w...

Страница 9: ...annels The effective voltage swing seen by the load is thus doubled so that the power output is doubled When using the Servo Quad Amplifier in bridge stereo mode be sure to connect each loudspeaker as...

Страница 10: ...the energy in musical signals lies in its low frequency components next time you re listening to a piece of popular music contrast the level of kick drum and bass guitar to the other instruments When...

Страница 11: ...dB Ref vs frequency sweep 20 Hz 50 kHz 5 0000 4 0000 3 0000 2 0000 1 0000 0 0 1 000 2 000 3 000 4 000 5 000 0 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 1 000 10 100 1k 10k 50k Ap AUDIO PRECISION...

Страница 12: ...5000 0 0 10 100 1k 10k 20k Ap AUDIO PRECISION servo 4060 4120 THD N LEVEL W vs FREQ Hz THD Watts 40000 35000 30000 25000 20000 15000 10000 80 000 160 000 73 333 146 666 66 667 133 333 60 000 120 000 3...

Страница 13: ...PF 1 kHz rated output power 005 IMD SMPTE 4 1 60 Hz 7 kHz rated output power 015 3 Signal To Noise Ratio 22 Hz 22 kHz bandwidth dB below rated output power 95 dB 4 Frequency Response 20 Hz 50 kHz 0 3...

Страница 14: ...elength for Samson Technologies Corp Copyright 1997 Samson Technologies Corp Printed April 1997 Samson Technologies Corp 575 Underhill Blvd P O Box 9031 Syosset NY 11791 9031 Phone 1 800 3 SAMSON 1 80...

Отзывы: