![Samson 33-1 Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/samson/33-1/33-1_mounting-and-operating-instructions_3829730035.webp)
EB 2551-1 EN
7-1
Operation
7 Operation
Immediately after completing start-up or
placing the regulator back into service (see
the 'Start-up' section), the regulator is ready
for use.
Risk of burn injuries due to hot or cold com-
ponents and pipeline.
Regulator components and the pipeline may
become very hot or cold. Risk of burn inju
-
ries.
Î
Allow components and pipelines to cool
down or heat up.
Î
Wear protective clothing and safety
gloves.
Risk of personal injury due to pressurized
components and process medium escaping
under pressure.
Î
Do not loosen the control line while the
valve is pressurized.
Risk of hearing loss or deafness due to loud
noise.
Noise emission (e.g. cavitation or flashing)
may occur during operation caused by the
process medium and the operating condi-
tions.
Î
Wear hearing protection when working
near the valve.
WARNING
!
WARNING
!
WARNING
!
7.1 Adjusting the set point
Î
The required downstream pressure is set
by turning the set point adjuster (9) on
the pilot valve (8) using an open-end
wrench (width across flats SW 17)
Î
Turn the set point adjuster clockwise (
)
to increase the pressure set point.
Î
Turn the set point adjuster counterclock-
wise (
) to reduce the pressure set point.
A pressure gauge located on the down-
stream pressure side allows the adjusted set
point to be monitored.
Содержание 33-1
Страница 12: ...2 2 EB 2551 1 EN Markings on the device...
Страница 19: ...EB 2551 1 EN 3 7 Design and principle of operation Dimensional drawings L H D H2 Fig 3 3 Dimensions...
Страница 20: ...3 8 EB 2551 1 EN Design and principle of operation...
Страница 32: ...5 8 EB 2551 1 EN Mounting and assembly...
Страница 36: ...7 2 EB 2551 1 EN Operation...
Страница 46: ...11 2 EB 2551 1 EN Removal...
Страница 48: ...12 2 EB 2551 1 EN Repairs...
Страница 50: ...13 2 EB 2551 1 EN...
Страница 55: ......