Malfunctions
8 Malfunctions
Depending on the operating conditions, check the actuator at certain intervals to prevent
possible failure before it can occur. Operators are responsible for drawing up a test plan.
SAMSON's After-sales Service department can support you to draw up a maintenance plan
for your plant.
Troubleshooting
Malfunction
Possible reasons
Recommended action
Actuator stem does not move on
demand.
Actuator is blocked.
Check attachment.
Unblock the actuator.
Insufficient signal pressure
Check the signal pressure.
Check the signal pressure line for
leakage.
Signal pressure not connected to
the correct diaphragm chamber.
See section 3.1 and section 5.2.
Actuator stem does not stroke
through its complete travel
range.
Travel stop active
See section 6.4.
Insufficient signal pressure
Check the signal pressure.
Check the signal pressure line for
leakage.
Valve accessories incorrectly set. Check the actuator without valve
accessories.
Check the settings of the valve
accessories.
Contact SAMSON's After-sales Service department for malfunctions not listed in the table.
Tip
Note
Содержание 3271-5
Страница 11: ...EB 8310 1 EN 11 Markings on the device...
Страница 19: ...EB 8310 1 EN 19 Design and principle of operation...
Страница 23: ...EB 8310 1 EN 23 Preparation...
Страница 37: ...EB 8310 1 EN 37 Operation A51 Stem connector A60 Handwheel A60 A51 Fig 11 Type 3271 5 Actuator with handwheel...
Страница 45: ...EB 8310 1 EN 45 Malfunctions...
Страница 51: ...EB 8310 1 EN 51...