3.4 Pump performance
The pump performance can easily be found using the performance curves.
• Plot in the lifting height and add the calculated pressure drop in meter water column.
• Follow a horizontal line till you meet the performance curve.
• Go vertical down and read the performance.
For practical design it is important that the speed in the pipe system etc. is verified against a fish handling
perspective.
Note: 1 meter water column = 0,1 bar = 100 mbar
DOC1627419_1
3.3 Service liquid pump
The water pump must be able to have a flow on 3000 l/h at a pressure at 1 bar(g) in order to get the full
performance of the liquid ring pump.