20
DOC9063L |
Ocean Master 1000
5 SERVICE, OPERATION, MAINTENANCE AND
INSPECTION INTERVALS
A failure to observe the inspection intervals described in table below may result in
damage to the pump
Section
Operation
Interval
5.1
Check grease cartridges (if equipped) - Only belt drive
Weekly
5.2
Winterization
When below 0°C
5.3
Lubrication of bearings - Only belt drive
Per 500 duty hours
5.4
Inspection and cleaning of service liquid’s supply pipe
Monthly
5.5
Inspection and cleaning of internal channels
Monthly
5.1 Check grease cartridges - Only belt drive
DOC3707
5.2 Winterization
If the pump needs to be used at a temperature below freezing point of the service liquid, it is necessary to
protect the liquid from freezing by adding anti freeze liquid.
If the pump is equipped with an automatic lubrication feature. It must be inspected and
replaced as needed.
When the pump is commissioned for the first time, the cartridges must be activated by
turning the arrow in the clockwise direction.
The cartridge is set to 12, which corresponds to an emptying time of 12 months.
The cartridge must be replaced when empty.
It is only allowed to use automatic lubricator of type
LAGD 125/WA2
.
The pipe connection between the liquid separator and pump must be inspected at least once a month, and
any contaminants must be removed.
5.4 Inspection and cleaning of service liquid’s supply pipe
Over-lubrication of bearings may result in bearing damage! Do NOT exceed the
amount of grease specified below!
5.3 Lubrication of bearings - Only belt drive
The bearings must be lubricated with grease of type SKF LGWA2, per 500 duty hours.
It is recommended to lubricate the bearings while pump is running.
DOC1619221_2
DE
NDE
DOC1619221_2
Lubrication interval per 500 duty hours
Drive end (DE)
16 g
Non drive end (NDE)
8 g
Содержание OCEAN MASTER 1000
Страница 37: ...37 DOC9063L Ocean Master 1000 Notes ...
Страница 38: ...38 DOC9063L Ocean Master 1000 Notes ...
Страница 39: ...39 DOC9063L Ocean Master 1000 Notes ...