Switchers

UNPACKING AND INSTALLATION

REMOVAL AND STORAGE

MAINTENANCE

The box contains:

 

- Device

 

- Power corde

 

- User manual (optional)

Before use, check the contents of the box. For any deficiency report to the seller or the manufacturer 

of the product.

DEVICE IS INSULATED BY PROTECTIVE WRAP AND PACKED IN A CARDBOARD BOX.

DEVICE IS SENSITIVE TO SHAKES AND DROPS. HANDLE WITH CARE DURING TRANSPORT 

AND ASSEMBLY.

Check if the product is damaged during transport.

1.  Before dismantling the device, switch off the power, remove 

the power cord and remove all other connectors.

2.  Remove the four screws for fastening.

3.  Remove the device from rack cabinet.

4.  Wrap the machine in the foil to protect it from dust. Package 

it in a box.

5.  The device must be stored in a room without moisture.

The system maintains only person authorized by Sams elektronik 

doo.

Any voluntarily opening device, upgrading or servicing is strictly 

prohibited and is subject to warranty void, and the possibility of 

injury.

Places for fastening

PROCEDURES FOR SAFE USE OF THE DEVICE:

1.  - Remove the protective wrap from the chassis.

 

- For devices that are AC 230V / 50Hz powered, the device is supplied with power cord. 

 

- Use only power corde that comes with the device.

2.  Device is mounted in a 19“ special-purpose rack cabinets designed for this type of device. Screw 

device with four screws. Screws for fastening are not supplied with the device.

3.  The device must be connected to ground. A device that is not connected to the grounding does 

not function properly according to factory declarations and can cause adverse effects on users and 

other equipment.

4.  Strictly comply to all steps for proper connection of devices in the system.

Illustration - mounted device

Содержание HDS-4

Страница 1: ... 29 october 2014 Z10 3 edition 1 Code 002 001 ENGLISH Sams elektronik d o o 48 Zivka Davidovica st 11050 Belgrade Serbia Tel Fax 381 11 3806 253 381 11 2402 212 sams sams rs www sams rs USER MANUAL FOR USE AND MAINTENANCE Read the instructions before using the device Keep this manual for periodic usage ...

Страница 2: ...er servicer has not completed repair or replacement within a reasonable time or if the manufacturer servicer did not perform repair or replacement without significant inconvenience to the consumer 5 The consumer may not terminate the contract if the lack of conformity of the product is negligible 6 The product will function properly when used in accordance with the user manual 7 Period of servicin...

Страница 3: ...h voltage In poor conditions the user may be exposed to shock The symbol exclamation mark in a triangle is to alert the user to comply by the terms of use in user s manual which is supplied with the device SAFETY WARNINGS ELECTRICAL SHOCK HAZARD DO N OT O PEN CAUTION RIZIK OD S TRUJNOG UDARA NE O TVARATI DOK JE P OD N APONOM UPOZORENJE CLASS I DEVICE Grounding is connected to the chassis of the de...

Страница 4: ...e is equipped with a protective fuse in the power outlet Do not bypass fuse 12 Do not replace the fuse Replacement can be made by a person authorized by the manufacturer 13 Do not bend the power cord so that it can be damaged 14 Connect connectors as in the enclosed instructions Deviations from the allowed values predicted for the inputs and outputs of the device can cause severe damage and warran...

Страница 5: ...ND STORAGE 6 DESCRIPTION 7 INSTALLATION 8 CABLE CONNECTION BETWEEN SWITCHER AND REMOTE 8 REMOTE CONTROL SCU 4 9 CONFIGURATION AND CONNECTION GRAPHIC EXAMPLE 10 NETWORK SETUP 11 NETWORK ACCESS AND DEVICE CONTROL 11 PROBLEMS AND SOLUTIONS IN A NETWORK ENVIRONMENT 13 SOFTWARE SUPPORT 15 NOTES 16 Page Description TABLE OF CONTENTS ...

Страница 6: ...device must be stored in a room without moisture The system maintains only person authorized by Sams elektronik doo Any voluntarily opening device upgrading or servicing is strictly prohibited and is subject to warranty void and the possibility of injury Places for fastening PROCEDURES FOR SAFE USE OF THE DEVICE 1 Remove the protective wrap from the chassis For devices that are AC 230V 50Hz powere...

Страница 7: ...001 Weight 1 5 Kg Type 1RU rack frame Dimensions 1RU x 19 x 100mm Required remote control SCU 4 Delivery includes device power corde user manual INPUT Number 4 Signal type HD SDI per SMPTE 292M SMPTE 259 EQ Automatic to 100m with Belden 1694A cable Impedance 75Ω Connectors BNC OUTPUT Number 1 dual Connectors BNC Impedance 75Ω Output level 800mV 10 Jitter 0 2UI at 100KHz Specifications and designs ...

Страница 8: ...N BLINK no signal Connect the power cord The device works only on AC 230 V 50 Hz Connect all necessary connectors before the unit is turned on Turn on the device by pressing power switch Status is represented by LEDs on the front side video inputs video output external reference TCP IP HDS 4 rear side connection with remote control HDS 4 front side Buttons to select an input Remote control SCU 4 f...

Страница 9: ...HDS Sams elektronik d o o sams sams rs www sams rs elektronik 9 Switchers REMOTE CONTROL SCU 4 The connection to the switcher ...

Страница 10: ...SE 500m A AC 2 30V 50Hz POWER REMOTE NETW ORK TCP IP EXT REF INPUT 4 3 2 1 OUTPUT B A www sam s rs Made in Serbia HDS 4 CODE 002 001 SN RISK OF EL EC TR IC SH OC K DO NO T OP EN CAUTION MACADDRESS PC Remote control HD SD SDI switcher CONFIGURATION AND CONNECTION GRAPHIC EXAMPLE ...

Страница 11: ...e desired device and press the Web Browser located on the left side of the software Browser will display the configuration options NOTE The device will be found from across the network only if the device was connected to a network cable before turning on If the program NETFINDER does not find the device on the network try the following Connect the inserter directly to the computer The computer set...

Страница 12: ...ects the selected input to the output Status REF PAL NTSC with yellow background BB 1080i with green background 3 level sync No Ref with red background No reference Communication status Green field ONLINE changing letters from small to large as long as there is communication with the device In this way we have an overview on state of the connection If the letter does not change communication is st...

Страница 13: ...NDER is not able to locate the device in the network try the following 1 Right click on Local Area Connection 2 Select option Change Windows Firewall settings 3 When a window Windows Firewall opens select tab Exceptions 4 Click on button Add program PROBLEMS AND SOLUTIONS IN A NETWORK ENVIRONMENT ...

Страница 14: ...255 0 default gateway and DNS leave blank 5 Turn off all kinds of firewalls completely 6 Install Tiny DHCP server 7 In Tray icon will appear in the form of two shaking hands 8 Click on that icon 9 In the opened window click the button Add new 10 Enter the MAC address of the device MAC address is entered without dashes dots and spaces and press OK 11 If the field is not marked with the MAC address ...

Страница 15: ...back about status of word clock Enter in form ref Feedback is 1 PAL 2 NTSC 3 480p 4 576p 5 720p 6 1080i 7 1080p EXAMPLE http ip_adresa get_data dst00 0 This means first input selected 17 If the tray icon of DHCP server has not changed its color when you turn the device turn the unit off wait for a while and turn it on again 18 Start application NETFINDER Tiny DHCP server is free software which is ...

Страница 16: ...HDS elektronik Sams elektronik d o o sams sams rs www sams rs 16 Switchers NOTES ...

Отзывы: