background image

DAA

elektronik

Sams elektronik d.o.o. • [email protected] • www.sams.rs

4

Distribution amplifiers

TECHNICAL SUPPORT AND SERVICE

Sams elektronik has made every effort to ensure that the equipment works in perfect condition. In 

the event that problems that occur can not be resolved, or if you have any questions regarding this 

equipment or information about other products produced from Sams elektronik, contact your local sales 

representative or call Sams elektronik directly through one of the ways listed below:

Sales: +381 11 3806 254

Technical support: +381 11 2402 212

Service: +381 11 4056 051

Email: 

Sales - [email protected]

Technical support and service - [email protected]

Web site: www.sams.rs

Address: 

SAMS ELEKTRONIK d.o.o.

48 Zivka Davidovica st

11050 Belgrade

Serbia

WARNING

TO AVOID ELECTRIC SHOCK, DO NOT OPEN COVER.

DEVICE MAINTENANCE REQUIRES PROFESSIONAL PERSON AUTHORIZED BY THE MANUFACTURER.
1.   Read all safety and operating instructions before using the device.

2.   Keep all safety and operating instructions.

3.   Follow the instructions from the user manual.

4.   Do not upgrade device, except in the case advised by the manufacturer.

5.   Do not use the device in the presence of water and / or moisture.

6.  Do not pour water or moisten the device with any type of liquid.

7.   Openings on device are provided for ventilation.

8.  Do not block air flow through the ventilation openings.

9.   This product is powered by AC ~ 230V ± 10%, 50Hz.

10.   This product is equipped with a three-wire cord with grounding.

11.  This device is equipped with a protective fuse in the power outlet. Do not bypass fuse.

12.  Do not replace the fuse. Replacement can be made by a person authorized by the manufacturer.

13.   Do not bend the power cord so that it can be damaged.

14.  Connect connectors as in the enclosed instructions. Deviations from the allowed values predicted 

for the inputs and outputs of the device can cause severe damage and warranty void.

15.  Do not use the device in an environment that contains flammable or explosive materials in any 

physical state.

16.   Turn off the power corde before cleaning. Do not use liquid, aerosol or flammable cleaners. Use 

only a dry cloth.

17.   Servicing  is  performed  by  a  qualified  person.  Removing  the  cover  user  is  exposed  to  high 

voltages.

18.   Never use the device when the cover is open and the device is powered on.

19.  Do not expose to extreme high or low temperatures.

20.  Do not expose to sudden temperature changes.

21.   Call service in the following cases:

 

- The power cord or plug is damaged

 

- Liquid or foreign objects is inside the device

 

- The machine is exposed to water and moisture

 

- The device does not function according to specification

 

- The unit has been dropped or damaged

 

- The characteristics are significantly changed 

22.   Use only specified replacement parts. 

23.   Professional person authorized by the manufacturer must check the device after completion of 

service.

24.   Allow a free rack unit (1RU) above and below the device for ventilation or put rack fan under the 

device.

Pictures and drawings listed in this user manual are for information purposes only and may differ 

from the actual device. Design and specifications of the device may change without prior notice.

Содержание DAA-106

Страница 1: ...8 april 2013 Updated 03 july 2014 Z10 3 edition 1 Code 001 103 001 108 007 159 007 160 007 161 ENGLISH Sams elektronik d o o 48 Zivka Davidovica st 11050 Belgrade Serbia Tel Fax 381 11 3806 253 381 11...

Страница 2: ...facturer servicer has not completed repair or replacement within a reasonable time or if the manufacturer servicer did not perform repair or replacement without significant inconvenience to the consum...

Страница 3: ...pplied with the device SAFETY WARNINGS FOR SRU RACK FRAME ELECTRICAL SHOCK HAZARD DO N OT O PEN CAUTION RIZIK OD S TRUJNOG UDARA NE O TVARATI DOK JE P OD N APONOM UPOZORENJE CLASS I DEVICE Grounding i...

Страница 4: ...device is equipped with a protective fuse in the power outlet Do not bypass fuse 12 Do not replace the fuse Replacement can be made by a person authorized by the manufacturer 13 Do not bend the power...

Страница 5: ...iers UNPACKING AND INSTALLATION 6 MAINTENANCE 6 REMOVAL AND STORAGE 6 DESCRIPTION 7 MODULE INSTALATION IN SRU RACK FRAMES 12 BACK CONNECTORS 14 SRU REAR SIDE 15 BLOCK DIAGRAM 16 PCB WITH THE LAYOUT OF...

Страница 6: ...uthorized by Sams elektronik doo Any voluntarily opening device upgrading or servicing is strictly prohibited and is subject to warranty void and the possibility of injury Places for fastening PROCEDU...

Страница 7: ...compatible Connector 3 pin terminal strip Impedance 75 Max level 7V p p Min level 0 2V p p AES3 110 OUTPUT Connector 3 pin terminal strip Impedance 110 Nominal level 3 1V p p 10 Rising time 4 s to 31...

Страница 8: ...compatible Connector 3 pin terminal strip Impedance 75 Max level 7V p p Min level 0 2V p p AES3 110 OUTPUT Connector 3 pin terminal strip Impedance 110 Nominal level 3 1V p p 10 Rising time 4 s to 31...

Страница 9: ...SPDIF compatible Connector BNC Impedance 75 Max level 7V p p Min level 0 2V p p AES3 110 OUTPUT Connector 3 pin terminal strip Impedance 110 Nominal level 3 1V p p 10 Rising time 4 s to 31 s Symmetry...

Страница 10: ...SPDIF compatible Connector BNC Impedance 75 Max level 7V p p Min level 0 2V p p AES3 110 OUTPUT Connector XLR or 3 pin terminal strip Impedance 110 Nominal level 3 1V p p 10 Rising time 4 s to 31 s Sy...

Страница 11: ...UT SPDIF compatible Connector BNC Impedance 75 Max level 7V p p Min level 0 2V p p AES3 110 OUTPUT Connector XLR or 3 pin terminal strip Impedance 110 Nominal level 3 1V p p 10 Rising time 4 s to 31 s...

Страница 12: ...IN SRU RACK FRAMES Make sure that the module is set to the correct place in relation to the back connector BEFORE INSTALLING OR REMOVING THE MODULE FROM SRU ALWAYS TURN OFF THE POWER Lock module with...

Страница 13: ...ms sams rs www sams rs elektronik 13 Distribution amplifiers 1 2 3 1 The module set between the guides not metal plate 2 Locking lever mount behind the groove 3 Push the lever to lock in an upright po...

Страница 14: ...06 DAA 106 DAA 106 DAA 106 DAA 106 DAA 106 DAA 106 DAA 106 DAA 106 DAA 106 DAA 106 DAA 106 IN G DAA 104 G AUDIO OUT 1 G AUDIO OUT 2 G AUDIO OUT 3 G AUDIO OUT 4 DAA 106 DAA 106 DAA 106 DAA 106 DAA 106...

Страница 15: ...5 screw 1 Mass 2 Power switch 3 The socket 4 Connections for back connectors Rear side view SRU REAR SIDE DO NOT INSERT SHARP METAL OBJECTS OR FINGERS INTO THE SPACE BEHIND THE POWER PANEL THE SIGN LI...

Страница 16: ...ice of the impedance of the input signal 110 75 Set the jumper for 75 5 The choice of the impedance of the output signal set jumper to position 2 3 75 1 2 110 JMP4 1 output JMP3 2 output JMP6 3 output...

Страница 17: ...the device by pressing switch If everything is OK LEDs will illuminate LOCK the presence of an incoming signal POWER Power indicator 1x6 AES EBU distribution amplifier 3x DAA 36 www sams rs POWER LOCK...

Страница 18: ...DAA elektronik Sams elektronik d o o sams sams rs www sams rs 18 Distribution amplifiers NOTES...

Отзывы: