TECHNICAL SUPPORT AND SERVICE

Sams elektronik has made every effort to ensure that the equipment works in perfect condition. In 

the event that problems that occur can not be resolved, or if you have any questions regarding this 

equipment or information about other products produced from Sams elektronik, contact your local sales 

representative or call Sams elektronik directly through one of the ways listed below:

Sales: +381 11 3806 254

Technical support: +381 11 2402 212

Service: +381 11 4056 051

Email: 

Sales - [email protected]

Technical support and service - [email protected]

Web site: www.sams.rs

Address: 

SAMS ELEKTRONIK d.o.o.

48 Zivka Davidovica st

11050 Belgrade

Serbia

WARNING

TO AVOID ELECTRIC SHOCK, DO NOT OPEN COVER.

DEVICE MAINTENANCE REQUIRES PROFESSIONAL PERSON AUTHORIZED BY THE MANUFACTURER.
1.   Read all safety and operating instructions before using the device.

2.   Keep all safety and operating instructions.

3.   Follow the instructions from the user manual.

4.   Do not upgrade device, except in the case advised by the manufacturer.

5.   Do not use the device in the presence of water and / or moisture.

6.  Do not pour water or moisten the device with any type of liquid.

7.   Openings on device are provided for ventilation.

8.  Do not block air flow through the ventilation openings.

9.   This product is powered by AC ~ 230V ± 10%, 50Hz.

10.   This product is equipped with a three-wire cord with grounding.

11.  This device is equipped with a protective fuse in the power outlet. Do not bypass fuse.

12.  Do not replace the fuse. Replacement can be made by a person authorized by the manufacturer.

13.   Do not bend the power cord so that it can be damaged.

14.  Connect connectors as in the enclosed instructions. Deviations from the allowed values predicted 

for the inputs and outputs of the device can cause severe damage and warranty void.

15.  Do not use the device in an environment that contains flammable or explosive materials in any 

physical state.

16.   Turn off the power corde before cleaning. Do not use liquid, aerosol or flammable cleaners. Use 

only a dry cloth.

17.   Servicing  is  performed  by  a  qualified  person.  Removing  the  cover  user  is  exposed  to  high 

voltages.

18.   Never use the device when the cover is open and the device is powered on.

19.  Do not expose to extreme high or low temperatures.

20.  Do not expose to sudden temperature changes.

21.   Call service in the following cases:

 

- The power cord or plug is damaged

 

- Liquid or foreign objects is inside the device

 

- The machine is exposed to water and moisture

 

- The device does not function according to specification

 

- The unit has been dropped or damaged

 

- The characteristics are significantly changed 

22.   Use only specified replacement parts. 

23.   Professional person authorized by the manufacturer must check the device after completion of 

service.

24.   Allow a free rack unit (1RU) above and below the device for ventilation or put rack fan under the 

device.

Pictures and drawings listed in this user manual are for information purposes only and may differ 

from the actual device. Design and specifications of the device may change without prior notice.

Содержание AA-101

Страница 1: ...de Serbia Tel Fax 381 11 3806 253 381 11 2402 212 sams sams rs www sams rs Copyright 1999 2014 Sams elektronik d o o Published 05 april 2013 Updated 03 july 2014 Z10 3 edition 1 Code 001 202 001 210 001 204 001 207 ENGLISH USER MANUAL FOR USE AND MAINTENANCE Read the instructions before using the device Keep this manual for periodic usage ...

Страница 2: ...ufacturer servicer has not completed repair or replacement within a reasonable time or if the manufacturer servicer did not perform repair or replacement without significant inconvenience to the consumer 5 The consumer may not terminate the contract if the lack of conformity of the product is negligible 6 The product will function properly when used in accordance with the user manual 7 Period of s...

Страница 3: ...upplied with the device SAFETY WARNINGS FOR SRU RACK FRAME ELECTRICAL SHOCK HAZARD DO N OT O PEN CAUTION RIZIK OD S TRUJNOG UDARA NE O TVARATI DOK JE P OD N APONOM UPOZORENJE CLASS I DEVICE Grounding is connected to the chassis of the device The power supply is protected with fuse against overload DECLARATION OF CONFORMITY for product SRU RACK FRAME WITH POWER SUPPLY PSU 212 WITH CORRESPONDING MOD...

Страница 4: ... device is equipped with a protective fuse in the power outlet Do not bypass fuse 12 Do not replace the fuse Replacement can be made by a person authorized by the manufacturer 13 Do not bend the power cord so that it can be damaged 14 Connect connectors as in the enclosed instructions Deviations from the allowed values predicted for the inputs and outputs of the device can cause severe damage and ...

Страница 5: ...lektronik 5 Page Description TABLE OF CONTENTS UNPACKING AND INSTALLATION 6 MAINTENANCE 6 REMOVAL AND STORAGE 6 DESCRIPTION 7 MODULE INSTALATION IN SRU RACK FRAMES 11 BACK CONNECTORS 13 SRU REAR SIDE 14 BLOCK DIAGRAM 15 PCB WITH THE LAYOUT OF ELEMENTS 16 ADJUSTMENT 16 NOTES 17 ...

Страница 6: ...authorized by Sams elektronik doo Any voluntarily opening device upgrading or servicing is strictly prohibited and is subject to warranty void and the possibility of injury Places for fastening PROCEDURES FOR SAFE USE OF THE DEVICE 1 If the device is not supplied with SRU rack frame remove the protective wrap from the device If the device is supplied with SRU rack frame remove the protective wrap ...

Страница 7: ...ction 80dB at 50Hz OUTPUT Number 6 electronically balanced Impedance 60Ω or 600Ω Output to output isolation 70dB at 20Hz to 20KHz Max output level 24 16dBU 600Ω PERFORMANCE Gain 6dB do 6dB Frequency response 0 1dB 20Hz to 20KHz S N ratio 100dB unity gain 20Hz to 20KHz TDH 0 05 at 20Hz to 20KHz Inter channel cross talk 90dB at 20Hz to 20KHz POWER Voltage 2 x 12V AC Power 7W TEMPERATURE Performance ...

Страница 8: ...balanced Common mode rejection 80dB at 50Hz OUTPUT Number 6 electronically balanced Impedance 60Ω or 600Ω Output to output isolation 70dB at 20Hz to 20KHz Max output level 24 16dBU 600Ω PERFORMANCE Gain 6dB do 6dB Frequency response 0 1dB 20Hz to 20KHz S N ratio 100dB unity gain 20Hz to 20KHz Inter channel cross talk 90dB at 20Hz to 20KHz POWER Voltage 2 x 12V AC Power 7W TEMPERATURE Performance 5...

Страница 9: ...n 80dB at 50Hz OUTPUT Number 4 electronically balanced Impedance 60Ω or 600Ω Output to output isolation 70dB at 20Hz to 20KHz Max output level 24 16dBU 600Ω PERFORMANCE Gain 6dB do 6dB Frequency response 0 1dB 20Hz to 20KHz S N ratio 100dB unity gain 20Hz to 20KHz TDH 0 05 at 20Hz to 20KHz Inter channel cross talk 90dB at 20Hz to 20KHz POWER Voltage 2 x 12V AC Power 7W TEMPERATURE Performance 5 40...

Страница 10: ...0K balanced Common mode rejection 80dB at 50Hz OUTPUT Number 4 electronically balanced Impedance 60Ω or 600Ω Output to output isolation 70dB at 20Hz to 20KHz Max output level 24 16dBU 600Ω PERFORMANCE Gain 6dB do 6dB Frequency response 0 1dB 20Hz to 20KHz S N ratio 100dB unity gain 20Hz to 20KHz Inter channel cross talk 90dB at 20Hz to 20KHz POWER Voltage 2 x 12V AC Power 7W TEMPERATURE Performanc...

Страница 11: ...N IN SRU RACK FRAMES Make sure that the module is set to the correct place in relation to the back connector BEFORE INSTALLING OR REMOVING THE MODULE FROM SRU ALWAYS TURN OFF THE POWER Lock module with lever to the position NOTE NEVER PLACE MODULE TO PLACE OF THE POWER SUPPLY MODULE The label that indicates the place for power supply module FOR POWER SUPPLY ONLY WARNING ...

Страница 12: ... elektronik Sams elektronik d o o sams sams rs www sams rs 12 1 The module set between the guides not metal plate 2 Locking lever mount behind the groove 3 Push the lever to lock in an upright position The module is locked 1 2 3 ...

Страница 13: ...lanced Unbalancing audio outputs AA 101 t AA 104 t 6dB G 1 1 2 2 IN G AA 101 G AUDIO OUT 1 G AUDIO OUT 2 G AUDIO OUT 3 G AUDIO OUT 4 G AUDIO OUT 5 G AUDIO OUT 6 AA 101 AA 101 AA 101 AA 101 AA 101 AA 101 AA 101 AA 101 AA 101 AA 101 AA 101 AA 101 AA 101 AA 101 AA 101 AA 101 Be sure to install a protective pad before installing the back connectors ...

Страница 14: ...5 screw 1 Mass 2 Power switch 3 The socket 4 Connections for back connectors Rear side view SRU REAR SIDE DO NOT INSERT SHARP METAL OBJECTS OR FINGERS INTO THE SPACE BEHIND THE POWER PANEL THE SIGN LIGHTNING IN A TRIANGLE IS TO ALERT THE USER TO THE PRESENCE OF LIFE THREATENING HIGH POWER LABEL IS PLACED NEXT TO POWER PANEL HIGH VOLTAGE DANGER ...

Страница 15: ...AA Distribution amplifiers Sams elektronik d o o sams sams rs www sams rs elektronik 15 AA 101 t AA 104 t only on AA 101t only on AA 104t BLOCK DIAGRAM ...

Страница 16: ...of the common signal 4 Input DC AC coupling Input with or without suppressing DC component 2 3 4 1 PCB WITH THE LAYOUT OF ELEMENTS ADJUSTMENT Audio distribution is factory set to 0dB input 0dB output For adjust is used 1m cable To adjust the distribution in the system it is necessary to have Signal generator a signal which is brought to the input of the distribution Adequate measuring equipment ou...

Страница 17: ...AA Distribution amplifiers Sams elektronik d o o sams sams rs www sams rs elektronik 17 NOTES ...

Страница 18: ...AA Distribution amplifiers elektronik Sams elektronik d o o sams sams rs www sams rs 18 ...

Отзывы: