TROUBLE SHOOTING FLOW CHART VER1.0
4-
2
MAIN POWER
1. NO MAIN POWER
2. POOR LOAD REGULATION
Is the main power in power
saving mode
﹖
﹖
﹖
﹖
YES
Check the
output stage
210V
YES
Is the main power in over
load condition
﹖
﹖
﹖
﹖
YES
Is the main
power in under
Voltage
condition
﹖
﹖
﹖
﹖
Check IC713,
IC712, IC731
and circuit
NO
NO
YES
NO
Check the R.G.B.
input cable and
signal source
Is the Voltage of
C757(210V)
normal
﹖
﹖
﹖
﹖
Check IC711,
Q713,R723,R724,
R725,D713
Check Q713,
D713, ZD712
Is the voltage of
IC713,IC712 and
IC001 pin20,
pin25 4.5V
?
?
?
?
Is there pulse
output from pin6
of IC711
﹖
﹖
﹖
﹖
Check IC711
Check 208V VR731, C756
NO
YES
YES NO
Is the main power in protection mode
﹖
﹖
﹖
﹖
NO