background image

4

PROTECTION AND LOCATION OF YOUR SET

11.

Do not use this television set near water ... for example, near a bathtub, washbowl, kitchen sink, or laundry tub, in a

wet basement, or near a swimming pool, etc.

Never expose the set to rain or water.  If the set has been exposed to rain or water, unplug the set from the wall

outlet and refer servicing to qualified service personnel.

12. Choose a place where light (artificial or sunlight) does not shine directly on the screen.

13. Avoid dusty places, since piling up of dust inside TV chassis may cause failure of the set when high humidity persists.

14. The set has slots, or openings in the cabinet for ventilation purposes, to provide reliable operation of the receiver, to

protect it from overheating.  These openings must not be blocked or covered.

Never cover the slots or openings with cloth or other material.
Never block the bottom ventilation slots of the set by placing it on a bed, sofa, rug, etc.
Never place the set near or over a radiator or heat register.
Never place the set in 

enclosure, unless proper ventilation is provided.

PROTECTION AND LOCATION OF YOUR SET

15.1. If an outside antenna is connected to the television set, be sure the antenna system is grounded so as to provide some

protection against voltage surges and built up static charges, Section 810 of the National Electrical Code, NFPA No.
70-1975, provides information with respect to proper grounding of the mast and supporting structure, grounding of the
lead-in wire to an antenna discharge unit, size of grounding conductors, location of antenna discharge unit, connection
to grounding electrode, and requirements for the grounding electrode.

15.2. Note to CATV system installer : (Only for the television set with CATV reception)

This reminder  is provided to call  the CATV system 

attention  to  Article  820-40  of  the  NEC  that  provides

guidelines for  proper grounding and, in particular, specifies that the cable ground shall be connected to the grounding
system of the building, as close to the point of cable entry as practical.

16.

An outside antenna system should not be located in the vicinity of overhead power lines or other electric lights or power
circuits, or where it can fall into such power lines or circuits.  When installing an outside antenna system, extreme care
should be taken to keep from touching such power lines or circuits as contact with them might be fatal.

17.

For added protection for this television set during a lightning storm, or when it is left unattended and unused for long
periods of time, unplug it from the wall outlet and disconnect the antenna.  This will prevent damage due to lightning
and power-line surges.

ANTENNA
LEAD- IN WIRE

ANTENNA DISCHARGE
UNIT (NEC SECTION
810-20)

GROUNDING
CONDUCTORS
(NEC SECTION 810-21)

GROUND CLAMPS

POWER SERVICE GROUNDING
ELECTRODE SYSTEM
(NEC ART 250. PART H)

ELECTRIC SERVICE

EQUIPMENT

GROUND CLAMP

NEC-NATIONAL ELECTRICAL CODE

EXAMPLE OF ANTENNA GROUNDING AS PER

NATIONAL ELECTRICAL CODE

EXAMPLE OF ANTENNA GROUNDING AS PER NATIONAL ELECTRICAL CODE INSTRUCTIONS

a   built-in

installer s

Содержание SC-29FA15

Страница 1: ...Procedure 21 5 Block Diagram 224 6 Schematic Diagram 25 7 PCB Layout 26 8 Exploded View Diagram 27 This manual is the latest at the time of printing and does not include the modification which may be...

Страница 2: ...of uninsulated voltage within the products enclosure that may be of sufficient magnitude to constitute a risk of electric shock to the person The exclamation point within an equilateral triangle is i...

Страница 3: ...nnel 8 Do not subject your television set to impact of any kind Be particularly careful not to damage the picture tube surface 9 Unplug this television set from the wall outlet before cleaning Do not...

Страница 4: ...porting structure grounding of the lead in wire to an antenna discharge unit size of grounding conductors location of antenna discharge unit connection to grounding electrode and requirements for the...

Страница 5: ...21 If you are unable to restorenormal operation by following the detailedprocedurein your operating instructions do not attempt any further adjustment Unplug the set and call your dealer or service te...

Страница 6: ...oise Reduction Picture Display Display Type DV CRT FSQ Screen Format 4 3 Size Visual size vis cm 25 Deflection System CRT only Tube Technology CRT only Black Matrix Iron CRT Defl CRT Gun Stand Gun CRT...

Страница 7: ...Cinch Audio Mono Out Cinch Dolby Surround Dig Audio Out Loudspeakers Control Busses Feature Slot ITV Smart Port Terr Antenna in 75 Ohms F type Guide IR Blaster Jack Connectors Front In Cinch CVBS St I...

Страница 8: ...tion Tests Local Integration Various Perf Param Service Call Rate PIP POP Type Features Digital Reception Transmission Built in Data System Text Standard Tele text Features Nbr bckgrnd page Mem Size T...

Страница 9: ...E04 SOFTWARE CODE 1 FOR IC001 PC 74 015020 50Q PLASTIC BAG 1 FOR CRT BD PACKING PC 74 060060 40F POLYBAG ANTISTATIC MAIN PCB 1 PC 75 326030 C00 SKD POLYFOAM 1 25 PC 76 002509 0AC CARTON BOX 0 084 PC 7...

Страница 10: ...1001 PC 10 1N4148 ABX DIODE 1N4148 SWITCHING 3 L501 FOR TO P503 1 PC 11 A562TM 0BX TRANSISTOR 2SA562TM 0 1 Q507 PC 11 SC1815 YBX TRANSISTOR 2SC1815 Y NPN 3 Q502 Q504 Q506 PC 11 SC4544 0AX TRANSISTOR 2...

Страница 11: ...KE 600 UH 1 L413 PC 37 SC2701 68V01 FBT BSC27 0168V 1 T402 PC 75 388320 CC0 POLYFOAM BOARD 0 05 FOR PMC PC 89 242080 JZ0 TRANSPARENT PACKING 6CMX41M 1 3 FOR PMC M 07 457FF5 NX7G ALPS FS TUNER TEDH9 24...

Страница 12: ...1 2 PC 72 BT17A6 C039A OPERATION MANUAL 1 PC 74 010050 40C POLYBAG FOR POWER 10CMX50CM 1 PC 74 022032 6WEAD PLASTIC BAG 1 PC 74 130130 80HAA POLYBAG W SUFFOCATION WARNING 1 PC 75 444370 EC0 POLYFOAM...

Страница 13: ...RES C F 22K OHM 1 6W 5 1 R091 PC 18 CB0470 JNX RES C F 47 OHM 1 6W 5 1 R089 PC 25 BCB221 M1X CAP ELEC 220 UF 16V 20 1 C081 PC 25 BCB470 M1X CAP ELEC 47 UF 16V 20 1 C080 PC 40 BT18S6 IRA1XG IR RECEIVE...

Страница 14: ...DBX DIODE ZENER 6V2 1 2W 5 1 D207 PC 10 79C8V2 DBX DIODE ZENER 8V2 1 2W 5 1 D303 PC 10 GBY228 F0X DIODE GBY228 1 D411 PC 10 HS5V1B DBX DIODE 500MW 5 1HSB 1 D001 PC 11 2SA817 AAX TRANSISTOR 2SA817AY 1...

Страница 15: ...2 R008 R007 PC 18 CB0394 JNX RES C F 390K OHM 1 6W 5 1 R939 PC 18 CB0470 JNX RES C F 47 OHM 1 6W 5 1 R024 PC 18 CB0471 JNX RES C F 470 OHM 1 6W 5 3 R238 R103 R036 PC 18 CB0472 JNX CARBON RES C F 4 7K...

Страница 16: ...CAP ELEC 0 22UF 50V 10 1 C216 PC 25 MFB478 K1X CAP ELEC 50V 0 47UF 10 1 C246 PC 26 AIC221 KBX CAP CER 220 PF 500V 10 B 2 C433 C441 PC 26 AIC332 KBX CAP CER 3300 PF 500V 10 1 C402 PC 26 AIC391 KBX CAP...

Страница 17: ...ER 10MM 1 J001 PC 41 WJ0105 B00 WIRE BARE JUMPER 10 5MM 4 J608 J607 J018 J214A PC 41 WJ0110 B00 WIRE BARE JUMPER 11MM 7 J024 J028 J228 J613 J042PC 41 WJ0115 B00 WIRE BARE JUMPER 11 5MM 3 J912 J939 J03...

Страница 18: ...SB60 7109 1 DB801 PC 11 C144ES 0BX TRANSISTOR PDTC144ES NPN 2 Q804 Q803 PC 11 P08P06 0AX TRANSISTOR SPP08P06P 1 Q802 PC 11 SK3451 0CX TRANSISTOR 2SK3451 01MR 1 Q801 PC 13 000TL4 31T IC TL431ACLP 1 IC8...

Страница 19: ...825A C807 PC 26 AMM221 JZX CAP CER 220PF 2KV 5 SL 2 C831 C852 PC 26 AMM331 JZX CAP CER 330 PF 2KV 5 SL 1 C834 PC 26 AMM561 KDX CAP CER 560 pF 2KV 10 D 1 C817 PC 26 APK102 ME4 CAP CER 1000PF 400VAC 20...

Страница 20: ...2 FOR T801 PC 66 343730 0B0 HOLLOW RIVET 1 6MMX3 0MMX3 2M 6 FOR T803 1 9 7 10 12 18 PC 66 343730 0B0 HOLLOW RIVET 1 6MMX3 0MMX3 2M 7 FOR C801 1 2 FOR RT801 PC 66 382330 0B7 RIVET 2 0X3 7X3 5 8 FOR IC8...

Страница 21: ...lance adjustment Mode Be used for White balance adjustment In Factory Mode press BUS OFF to enter and exit Default Value OK mode Be used for default value setting before TV leaves Factory In Factory M...

Страница 22: ...t step 2 3 to make X 284 Y 299 Note M134 chassis can adjust white balance automatically In factory mode press I2C BUS to enter in The white balance in the other two colors temperature is Warm 296 296...

Страница 23: ...HPOS6 12 CNTX 7F BRTC 40 ST3 20 PARA6 16 CNTN 08 COLC 2C SV3 20 TRAP6 2B BRTX 20 COLP 00 SV4 19 HSIZE6 2C BRTN 20 SCOL 07 SVD 19 CNRT6 0B COLX 35 SCNT 0C ASSH 07 CNRB6 0D COLN 00 CNTC 4C SHPN 10 VEHT...

Страница 24: ...m Data Item Data Item Data RC C 80 RC W 80 D COL 32 S COL 32 GC C 80 GC W 80 D BRI 32 S BRI 32 BC C 80 BC W 80 D CON 5A S CON 32 GD C 40 GD W 40 D SHP 32 S SHP 32 BD C 40 BD W 40 YUVGC 03 YUVBC 03 FAC...

Страница 25: ......

Страница 26: ......

Страница 27: ......

Отзывы: