12

8

CONNECTING SOLAR PANELS IN PARALLEL

 

The Samlex Expansion kits maybe used to 

increase the solar energy available to charge 

your batteries. Each Samlex Expansion kit 

comes with a solar panel, mounting hardware 

for the solar panel and a set of MC male and 

female branch connectors to parallel the solar 

panel to your existing system. 

1.  If the existing panel is already connected 

to the mating connector on the pre-

assembled cables provided in the 

original kit, remove this connection 

using using a tweezer or any other 

suitable tool.

2.  Connect the Positive leads (marked as 

‘+’) from the two solar panels to the 

suitable mating branch connector (as in 

fig 8.1.). 

3.  Connect the Negative leads (marked 

as ‘-’) from the two solar panels to the 

suitable mating branch connector (as in 

fig 8.1.).

4.  Mate the MC branch connectors to the 

corresponding mating MC connector on 

the pre-assembled cables provided with 

your original kit. 

Fig. 8.1. Connecting solar modules in parallel.

Additional

Solar Panel

Existing

Solar Panel

Negative MC

branch connector

Positive MC

branch connector

If the additional solar panels 

are required to be mounted at a 

distance from the existing solar 

panel, a pair of cables with a MC4 

connector pre-assembled at one 

end is provided.

1.  Cut the cable pair to the 

appropriate length. 

2.  Strip 0.25" of the insulation 

at the blunt ends using a 

suitable wire stripper.

3.  Crimp the male and female 

MC4 connector to the blunt 

end of the appropriate cable 

with a suitable wire crimping 

tool.

4.  Complete the connections as 

shown in Fig.8.2. 

Fig. 8.2. Connection solar modules in parallel with additional module.

Negative MC

branch connector

Positive MC

branch connector

Additional cable pair

Additional

Solar Panel

Existing

Solar Panel

Содержание SRV-50-KIT

Страница 1: ...Owner s Manual Please read this manual before operating your kit Solar Charging Kit SRV 50 KIT SRV 85 KIT SRV 120 KIT SRV EXP 50 KIT SRV EXP 85 KIT SRV EXP 120 KIT...

Страница 2: ...ts List 4 3 0 General Safety 6 4 0 Required Tools Materials 7 5 0 Charge Controller Installation 7 6 0 Wiring 8 7 0 Solar Panel Installation 10 8 0 Connecting Solar Panels in Parallel 12 9 0 Typical B...

Страница 3: ...r mounting within the RV interior The Samlex Solar RV kit also incorporates mounting hardware including sturdy aluminum Z brackets with the nuts and bolts required to flat mount the solar panel on the...

Страница 4: ...0 0 1 1 1 9 Positive MC branch connector 0 0 0 1 1 1 10 Negative MC Branch Connector 0 0 0 1 1 1 11 5 hole mounting bracket 4 4 4 4 4 4 12 Stainless Steel Serrated Flange bolt 20 x 4 4 4 4 4 4 13 Stai...

Страница 5: ...teries contain very corrosive diluted sulphuric acid as electrolyte Precautions should be taken to prevent contact with skin eyes or clothing Batteries generate hydrogen and oxygen during charging res...

Страница 6: ...ee Check and maintain the battery electrolyte levels at regular intervals as per the battery manufacturer s recommendations if flooded wet cell lead acid batteries are used Check and replace damaged c...

Страница 7: ...SCC 30AB to optimally charge your batteries from the solar panel 2 The Solar charge controller comes with its own detailed manual Read the manual in detail The instructions in this section are only a...

Страница 8: ...he Positive terminal marked BAT of the charge controller Negative lead is connected to the Negative terminal marked BAT of the Charge Controller SCC 30AB Crimp the battery ring terminals fig 6 1 2 pro...

Страница 9: ...dware safely as the vent cover will have to be replaced after the wire has been routed 8 The wire from the solar panel can be routed by either A Hole in the side of the vent Drill a suitable hole in t...

Страница 10: ...end fig 7 3 Tightening a conventional machine bolt or screw engages the captive nut thereby causing the bushing to expand outwards This fastens securely to thinner RV roofs by bulging up and against t...

Страница 11: ...o the roof surface by inserting the x1 serrated flange bolt into the Well Nut Tighten using a3 8 wrench to a recommended torque of 15 lbs When the serrated flange bolt is screwed into the Well Nut the...

Страница 12: ...as in fig 8 1 4 Mate the MC branch connectors to the corresponding mating MC connector on the pre assembled cables provided with your original kit Fig 8 1 Connecting solar modules in parallel Addition...

Страница 13: ...tery 3 Battery 2 Battery 4 Battery 1 Battery 3 Battery 2 Battery 1 Battery 2 Battery 4 Cable A Cable B Cable A Cable B Cable A Cable B Solar Charge Controller SCC30 AB rear view Solar Charge Controlle...

Страница 14: ...ies will charge at the same charging current and thus will be charged to the same state at the same time None of the batteries will see an overcharge condition If the positive output cable of the batt...

Страница 15: ...ble to remedy the defect after having a reasonable number of opportunities to do so Warranty service shall be performed only by the Warrantor Any attempt to remedy the defect by anyone other than the...

Страница 16: ...110 17 Fawcett Rd Coquitlam B C Canada V3K 6V2 T 604 525 3836 F 604 525 5221 e mail samlex samlexsolar com website www samlexsolar com 092 2009...

Отзывы: