3

2

Remove the external input side fuse F1 (Fig 4.1) in the Positive input wire.

 Connect the input side wires to the converter’s input side first. OBSERVE CORRECT POLARITY.

Connect the input wires to the battery.

 Insert the external input side fuse F1 (Fig 4.1) in the Positive input wire. NOTE: A spark may be observed 
when inserting the fuse due to the initial inrush current to charge the input side capacitors inside the 
converter.

Output voltage will now be available on the output side of the unit.

 Switch on the load.

5. SPECIFICATIONS

3.2 Temperature Compensated Current Limit

As the temperature of the main switching MOSFET increases, the value of the current limit decreases.

3.3 Over Voltage on the Output Side

If the output voltage increases beyond 16.5 V +/-0.5 V, a crowbar circuit will activate and blow the internal input 
side fuse (5, Fig 1.1) / external input side fuse F1 (Fig 4.1) will blow.

3.4 Over Voltage / Transients on the Input Side

The input side is protected against over voltage and transients through a Transient Voltage Suppressor. In case 
the input voltage exceeds 37 VDC, the internal input side fuse (5, Fig 1.1) / external input side fuse F1 (Fig 4.1) 
will blow.

3.5 Reversal of Polarity on the Input Side

In case the input side polarity is reversed, the internal input side fuse (5, Fig 1.1) / external input side fuse F1 
F1 (Fig 4.1) will blow.

4 INSTALLATION & OPERATION

4.1 General Installation Requirements

 This unit is cooled by convection. Install the unit in a cool, dry & well ventilated space. The ambient 
temperature should not exceed 40

o

C.

Do not install the unit inside the engine compartment

Do not connect / disconnect input and output connections when live voltages are present

4.2 Installation Diagram

Installation information is given at Fig 4.1 below:

Fig 4.1  Installation Diagram

CAUTION

!

Fuse F1 to be

within 7” from the 

Positive terminal

24V IN

GND

GND

13.8V OUT

24V BATTERY

+

F1

F2

+

+

To 12V Loads

+

INFO

For specs of fuses F1 and F2

and wiring sizes, see Specifications

at Section 5.

!

i

4.3 Making Input & Output Connections & Operation

!

  

CAUTION!

  

1. 

 

Please ensure that the polarity of the input connection is not reversed. Connect the Positive of the 
battery to the Positive terminal and the Negative of the battery to the Negative. In case the input 
polarity is reversed, internal input side fuse (5, Fig 1.1) / external input side fuse F1 (Fig 4.1) will blow.

 

2.  Input and output connections should not be made when live voltages are present.

 Switch off the load that is required to be powered from the converter

 Connect the output wires to the load and then to the output side of the unit through the external fuse F2 
(Fig 4.1). Observe correct polarity.

NOTES:

1. All power ratings are specified for resistive load at Power Factor = 1.
2. All specifications given above are at ambient temperature of 25

°

C / 77

°

F.

3. Specifications are subject to change without notice

MODEL NO. SDC-15

SDC-23

CAUTION!   There is no isolation between the input and the output sides. 

Input and output have common Negative.

OUTPUT

OUTPUT VOLTAGE 13.8 VDC ± 0.1V @ 12A

13.8 VDC ± 0.1V @ 20A

CONTINUOUS OUTPUT CURRENT 12A

20A

PEAK OUTPUT CURRENT 15A

23A

CURRENT LIMIT  16 ± 0.5A

24 ± 0.5A

LOAD REGULATION > 0.5%

< 0.5

INPUT

INPUT VOLTAGE 20 - 35 VDC

20 - 35 VDC

INPUT CURRENT AT NO LOAD < 150mA

< 150mA

LINE REGULATION < 0.5%

< 0.5%

EFFICIENCY 

(At maximum output)

> 88%

> 88%

RIPPLE < 10 mV P-P @ 12A

< 50 mV P-P @ 20A

NOISE < 40 mV P-P @ 12A

< 120 mV P-P @ 20A

FUSES

INTERNAL INPUT FUSE

 

(inside the fuse holder)

10A, 250V 

(Bussmann AGC-10 or equivalent)

15A, 250V 

(Bussmann AGC-15 or equivalent)

EXTERNAL INPUT FUSE 

(At the battery end - Not supplied)

10A, 32V 

(Automotive blade type: ATO/ATC)

15A, 32V

(Automotive blade type: ATO/ATC)

EXTERNAL OUTPUT FUSE 

(not supplied)

15A, 32V 

(Automotive blade type: ATO/ATC)

20A, 32V 

(Automotive blade type: ATO/ATC)

PROTECTIONS

OUTPUT OVERLOAD / SHORT CIRCUIT

•   Output current will be limited 

to 16 ± 0.5A

•   Output voltage will drop

•   Output current will be limited 

to 24 ± 0.5A

•   Output voltage will drop

INPUT OVER VOLTAGE Input side fuse(s) will blow at > 37 VDC Input side fuse(s) will blow at > 37 VDC

OUTPUT OVER VOLTAGE Input side fuse(s) will blow at 

> 16.5 ± 0.5 VDC

Input side fuse(s) will blow at 

> 16.5 ± 0.5 VDC

REVERSE POLARITY ON INPUT SIDE Input side fuse(s) will blow

WIRES

INPUT WIRE SIZE #12 AWG

#10 AWG

OUTPUT WIRE SIZE #10 AWG

#8 AWG

ENVIRONMENT

OPERATING ENVIRONMENT Indoor use

Indoor use

OPERATING TEMPERATURE RANGE 0 - 40

o

C / 32 - 104

o

F

0 - 40

o

C / 32 - 104

o

F

DIMENSIONS

(W X D X H), MM 198 x 122 x 60

198 x 122 x 60

(W X D X H), INCHES 7.8 x 4.8 x 2.4

7.8 x 4.8 x 2.4

WEIGHT

KG 0.9

1.0

LBS 2.0

2.2

!