PROTECTIVE FEATURES OF THE INVERTER 

 

OVER TEMPERATURE PROTECTION – If the temperature inside the inverter is too high, the 
unit will automatically shut down. Allow the unit to cool for at least 15 minutes before restarting 
after a heat-related shutdown. Unplug unit while cooling. 

 

LOW BATTERY VOLTAGE PROTECTION - This condition is not harmful to the inverter but 
could damage the power source. The inverter automatically shuts down when input voltage 
drops to 10.0 volts.   

 

OVER VOLTAGE PROTECTION – The inverter will automatically shut down when the input 
voltage exceeds 15.5 volts DC. Input voltage exceeds 16 volts could damage the inverter. 

 

OVERLOAD PROTECTION – The inverter will automatically shut down when the continuous 
draw exceeds rated watts. 

 

SHORT CIRCUIT PROTECTION – The inverter will shut down. Remove the short circuit and 
restart inverter. 

 

EARTH FAULT PROTECTION – This inverter comply with the standard current leakage 
allowance. When large current leakage to earth terminal occurs, the protection circuit activated 
and shut down the inverter, which prevent electric shock to human. Turn OFF the inverter, 
unplug the fault AC appliance and then turn ON is the only way to restart it. 

 

LOW BATTERY ALARM – An alarm will sound when the voltage from the battery drops to 10.6 
volts. This is an indication that the battery needs to be recharged. The user should stop 
operation of the electronic device at this time since the inverter will shut down automatically 
shortly thereafter, when the battery voltage drops to 10 volts. Start your engine to recharge the 
battery.  

If the low voltage alarm sounds when the battery is fully charged, follow the steps for solving 
lack of output power in the Troubleshooting guide. The alarm will sound when the inverter is 
overloaded, in thermal shutdown, or if there is an excessive voltage drop between the battery 
and inverter. 

NOTE: It is normal for the alarm to sound while the unit is being connected to, or disconnected 
from, the power source. This is not indicative of a problem.

 

 

10 

Содержание SAM-250-12

Страница 1: ...NS IMPORTANT INFORMATION REGARDING SAFETY OPERATION MAINTENANCE AND STORAGE OF THIS PRODUCT BEFORE USE READ AND UNDERSTAND ALL CAUTIONS WARNINGS INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BAT...

Страница 2: ...12 V DC cigarette plug connections and terminal connections 4 This is not a toy keep away from children 5 DO NOT install object into air vents CAUTIONS 1 Do not use with positive ground electrical sy...

Страница 3: ...vides full automatic inverter and battery protection This includes overheat protection battery protection overload protection short circuit protection and earth fault protection L I T greatly improves...

Страница 4: ...as modified sine wave It is a waveform that has characteristics similar to the sine wave shape of utility power This type of waveform is suitable for most AC loads including linear and switching power...

Страница 5: ...ll provide you 115 VAC when powered by a 12 VDC source such as is found in a vehicle or multiple battery configurations as shown in FIGURE 2 This manual does not describe all of the possible types of...

Страница 6: ...be mounted on a wall mount it horizontally so that indicators switches outlets and terminal blocks located on the front panel are visible and accessible If inverter is to be installed in a moving vehi...

Страница 7: ...o the positive terminal of the inverter 5 Connect a length of wire between the inverter s negative terminal and the DC power source negative terminal 6 Connect a short length of wire to the other term...

Страница 8: ...he inverter should only be used in locations that meet the following criteria DRY Do not allow water and or other liquids to come into contact with the power inverter In all marine applications do not...

Страница 9: ...rload if necessary turn the power switch OFF then ON DETERMINING BATTERY SIZE To determine the minimum battery size that you will need to operate appliances follow these steps 1 Determine the wattage...

Страница 10: ...e standard current leakage allowance When large current leakage to earth terminal occurs the protection circuit activated and shut down the inverter which prevent electric shock to human Turn OFF the...

Страница 11: ...YES YES YES YES 3000W NO YES YES YES YES Standard USB charging port 5Vdc 500mA Compatible with SAM Series remote control only Connect with incompatible remote cable will damage the power inverter remo...

Страница 12: ...corporates a higher quality power amplified supply TELEVISION INTERFERENCE The inverter is shielded to minimize interference with TV signals The problem may not be with the inverter However in some in...

Страница 13: ...Green LED lit Earth fault protection is activated by excessive current leakage from the load Unplug the faulted load Low battery alarm sounds abnormal Bad connection or wiring Tighten all DC connecti...

Страница 14: ...gh voltage and high temperature inside CAUTION NO USER SERVICEABLE COMPONENTS INSIDE DO NOT ATTEMPT TO OPEN THE INVERTER SPECIFICATIONS Output Connection North America AC Receptacle s Output Voltage A...

Отзывы: