SamplexPower PST-600-12 Скачать руководство пользователя страница 59

58  |  SAMLEX AMERICA INC.    

 

    

SAMLEX AMERICA INC.  |  59

SYMPTOMS

POSSIBLE CAUSE

REMEDY

• There is no AC output
• The Green LED marked 

"POWER" 

(2, Fig 6.1)

 is  

lighted

• Buzzer is on. 
• Status LED on the GFCI 

outlet 

(5C, Fig 6.1)

 is OFF

Shut-down due to high 
input DC voltage
•  DC input voltage is 

16.5V or higher for PST-
600-12

•  DC input voltage is 33V 

or higher for PST-600-24

Refer to precautions detailed at Section 8.4.1 
to prevent DC input over voltage
•  The unit will reset automatically when the 

DC input voltage drops below 16.5V for 
PST-600-12 or below 33V for PST-600-24

• AC output shuts down  

completely 

• Red LED marked  

"OVERLOAD" 

(3, Fig 6.1)

  

is lighted

• Buzzer alarm is ON
• Green LED marked "POWER 

ON" 

(2, Fig 6.1)

  

is lighted 

• Status LED on the GFCI 

outlet 

(5C, Fig 6.1)

 is OFF

Permanent shut-down of 
the AC output due to: 
• Continuous overload  

more than 110% - 
115% 

OR

• Short circuit on the AC  

load side

•  Reduce the load / remove the short circuit
•  The load is not suitable as it requires higher 

power to operate. Use an inverter with 
higher power rating. 

•  If the unit goes into permanent overload 

again after resetting and removing the load 
completely, the unit has become defective.  
Call Technical support. 

NOTE: 

The unit will be latched in this shut-

down condition and will require manual reset. 
To reset, switch OFF the power ON/OFF switch 

(1, Fig 6.1)

, wait for 3 minutes and then switch 

ON again. 
Before switching ON again, remove the cause  
of the shut-down.

• There is no AC output. 

Buzzer alarm is sounded. 
The Green LED marked  
"POWER" 

(2, Fig 6.1)

 is  

lighted. Green indication 
light on the GFCI is OFF.

• Buzzer alarm is ON
• Red LED marked "OVER 

TEMP" 

(4, Fig 6.1)

 is lighted

• Green LED marked "POWER 

ON" is lighted

• Status LED on the GFCI 

outlet 

(5C, Fig 6.1)

 is OFF

Shut-down due to over 
temperature because of 
fan failure or inadequate 
cooling as a result of high 
ambient temperature or 
insufficient air exchange
•  Internal hot spot is at 90 

±

 5

°

C or higher

Check that the fan is working. If not, the fan 
control circuit may be defective. Call  
Technical Support. 
If the fan is working, check that the ventilation 
slots on the suction side and the openings 
on the discharge side of the fan are not 
obstructed. 
If the fan is working and the openings are not 
obstructed, check that enough cool replace-
ment air is available. Also check that the ambi-
ent air temperature is less than 40ºC. 
Reduce the load to reduce the heating effect. 
After the cause of overheating is removed and 
the internal hot spot cools down to 65 

±

 5

°

C, 

the AC output will be restored automatically. 

…Continued on page 60

SECTION 11  |  

Troubleshooting Guide

Содержание PST-600-12

Страница 1: ...DC AC Power Inverter Pure Sine Wave PST 600 12 PST 600 24 Please read this manual BEFORE installing your inverter Owner s Manual...

Страница 2: ...RRANTY AS TO THE ACCURACY SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION 2 ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSSES DAMAGES CO...

Страница 3: ...sembly repair should be carried out by qualified personnel only Disconnect all AC and DC side connections before working on any circuits associated with the unit Turning the ON OFF switch on the unit...

Страница 4: ...leling of the AC Output The AC output of the unit should never be connected directly to an Electrical Breaker Panel Load Centre which is also fed from the utility power generator Such a direct connect...

Страница 5: ...nditions of high winds for wind generators high water flow rates for hydro generators It is therefore to be ensured that the diversion load is sized correctly to prevent the above over voltage conditi...

Страница 6: ...e L installation et le c blage doivent conformer aux Normes lectriques Locales et Nationales l installation doit tre faite par un e lectricien ne CERTIFI E 1 5 2 Pr vention des D charges lectriques Co...

Страница 7: ...ec les batteries Les batteries pourraient produire un court circuit assez puissant pour souder des objets causant une br lure grave Si vous devez enlever la batterie retirez toujours la borne n gative...

Страница 8: ...ectr iques Il faut donc s assurer que la charge de d rivation est correctement dimen sionn e pour viter les conditions de surtension ci dessus N utilisez pas de panneaux solaires pour charger directem...

Страница 9: ...degrees by which the current vector leads or lags the voltage vector in a sinusoidal voltage In a purely induc tive load the current vector lags the voltage vector by Phase Angle 90 In a purely capac...

Страница 10: ...vided by the AC source Hence the inverter AC wiring and over cur rent protection devices have to be sized based on the combined effect of the Active and Reactive Powers that is called the Apparent Pow...

Страница 11: ...ge of power with a value of up to 8 times the Maximum Continuous Running AC Power AC to DC Switched Mode Power Supplies SMPS This type of power supply is used as stand alone power supply or as front e...

Страница 12: ...orial sum of Active Power Watts and Reactive Power VAR The AC power source has to be sized based on the higher Apparent Power VA and also based on the Starting Surge Power 2 2 OUTPUT VOLTAGE WAVEFORMS...

Страница 13: ...e Wave with very low harmonic distortion and cleaner power like Utility Grid supplied electricity Inductive loads like microwaves motors transformers etc run faster quieter and cooler More suitable fo...

Страница 14: ...mmodate high short duration surge of power required during start up of certain AC appliances and devices Please read details of the above two types of power ratings in Section 2 1 under DEFINITIONS i...

Страница 15: ...h Grinder 3 Incandescent Halogen Quartz Lamps 3 Ceramic Positive Temperature Coefficient PTC type of heaters 5 Laser Printer Other Devices using Infrared Quartz Halogen Heaters 4 Switch Mode Power Sup...

Страница 16: ...of the inverter to the EMI receptors types and quality of connecting wires and cables etc EMI due to factors external to the inverter may be reduced as follows 3 2 1 EMI due to factors external to the...

Страница 17: ...n is not sinusoidal but non linear as shown in Fig 4 2 The steady state input current of SMPS is a train of non linear pulses instead of a sinusoidal wave These pulses are two to four milliseconds dur...

Страница 18: ...te input RMS current NOTE Voltage and current scales are different Fig 4 1 Inrush current in an SMPS TIME Peak Current RMS Current Non linear Input Current Pulse Input Sine Wave Voltage Crest Factor P...

Страница 19: ...gative direction and slowly increases in the Negative direction to a peak Negative value Vpeak 169 68V and then slowly drops back to 0V There are 60 such cycles in 1 sec Cycles per second is called th...

Страница 20: ...ton 5B Test Button 5C Dual Color Green Red Status LED for GFCI 6A Ventilation slots at the bottom for air suction for cooling fan 6B Cooling Fan Opening for air discharge 7 Grounding Lug Wire hole dia...

Страница 21: ...Gravity 1 120 for fully discharged condition 7 2 TYPES OF LEAD ACID BATTERIES 7 2 1 Sealed Lead Acid SLA Or Valve Regulated Lead Acid VRLA Batteries These can either be Gel Cell or AGM Absorbed Glass...

Страница 22: ...o repeatedly accept recharging They are marketed for use in recreation vehicles RV boats and electric golf carts so they may be referred to as RV batteries marine batteries or golf cart batteries 7 3...

Страница 23: ...A As the battery capacity is 100 Ah the battery will be completely discharged in 0 5 Hrs 1C 1x 100 A 100A As the battery capacity is 100 Ah the battery will be completely discharged in 1 Hr 0 2C or C...

Страница 24: ...xis shows State of Charge State of Discharge can be converted to State of Charge using formula State of Charge 100 State of Discharge e g 80 State of Discharge 100 80 20 State of Charge 7 7 2 Example...

Страница 25: ...1 0 20 0 19 0 18 0 24V 12V Fig 7 1 Charging Discharging Curves for Typical 12V 24V Flooded Lead Acid Battery 7 8 REDUCTION IN USABLE CAPACITY AT HIGHER DISCHARGE RATES TYPICAL IN INVERTER APPLICATION...

Страница 26: ...l actually last for 50 Ah 50 Amperes 1 Hour 7 9 STATE OF CHARGE SOC OF A BATTERY BASED ON STANDING VOLTAGE The Standing Voltage of a battery under open circuit conditions no charger or load connected...

Страница 27: ...voltage of the battery is dependent upon the following Temperature of the battery electrolyte Temperature of the electrolyte affects the electrochemical reactions inside the battery and produces a Ne...

Страница 28: ...y under load cannot be estimated accurately However the low DC input voltage alarm function is designed to protect the inverter from excessive current drawn at the lower voltage 7 12 LOW DC INPUT VOLT...

Страница 29: ...based on the actual application requirements Please consider using the following Programmable Low Battery Cut off Battery Guard Models manufactured by Samlex America Inc www samlexamerica com BG 40 4...

Страница 30: ...Positive terminal of battery 1 The Negative terminal of battery 1 becomes the Negative terminal of the 24V battery bank 7 15 2 Parallel Connection 12V 100 Ah Battery 1 Battery 3 Battery 2 Battery 4 12...

Страница 31: ...ention should be paid to the manner in which the inverter charger is connected to the battery bank Please ensure that if the Positive output cable of the inverter charger Cable A is connected to the P...

Страница 32: ...il faut faire attention la mani re dont le chargeur est branch la banque de batterie Veuillez assurer que le c ble positif de sortie du chargeur de batterie C ble A est li la borne positive de la prem...

Страница 33: ...tteries is the AC power delivered by the inverter to the load in Watts W divided by 10 for an inverter running from a 24V battery system the approximate DC current required from the 24V batteries is t...

Страница 34: ...most 2 times the energy required by the load in Ah Thus as a Rule of Thumb the Ah capacity of the batteries should be twice the energy required by the load in Ah 7 17 CHARGING BATTERIES Batteries can...

Страница 35: ...Please ensure that the following requirements are met Working Environment Indoor use Cool Heat is the worst enemy of electronic equipment Hence please ensure that the unit is installed in a cool area...

Страница 36: ...Accessibility Do not block access to the front panel Also allow enough room to access the AC receptacles and DC wiring terminals and connections as they will need to be checked and tightened periodica...

Страница 37: ...ng the unit vertically on a vertical surface is NOT allowed fan opening facing up or down As explained above this is to prevent falling of objects into the unit through the fan opening when the fan op...

Страница 38: ...ing slots are shown in Fig 8 1 below Fig 8 1 PST 600 Overall Dimensions Mounting Slots NOTE Dimensions are in mm PST 600 dimensions 200 14 0 5 0 14 0 5 0 32 12 162 32 12 1 6 9 5 5 276 2 NEG WARNING Re...

Страница 39: ...er between the solar panel array and the battery bank Using solar panel array to directly charge the battery will lead to over voltage shutdown of the inverter and possible damage due to battery volta...

Страница 40: ...la batterie soit complet les condensateurs commen eront recharger L appareil prendra un courant fort bri vement pour s alimenter qui va produire une tincelle sur le dernier contact du boucle d entr e...

Страница 41: ...due to the current the resistance of the length of the wire should be less than 2 Use oil resistant multi stranded copper wire wires rated at 90 C minimum Do not use aluminum wire as it has higher re...

Страница 42: ...require a corresponding fuse holder MRBF XXX Series fuses made by Cooper Bussmann may also be used These fuses comply with ISO 8820 6 for road vehicles WARNING Use of an appropriately sized external f...

Страница 43: ...uit It is mandatory to install this fuse within 7 of the battery Positive terminal to protect the battery cables against short circuit Amp rating of the fuse is based on the following considerations a...

Страница 44: ...be equal to or larger than the rated continuous DC input current of the inverter at Column 2 Further the Amp rating of the fuse used for protecting a battery cable against short circuit has to be lowe...

Страница 45: ...utomatic Transfer Switch Model No STS 30 is recommended for this application 2 To prevent possibility of paralleling and severe damage to the inverter never use a simple jumper cable with a male plug...

Страница 46: ...e GFCI used in this unit is Class A Self Monitoring Type as per UL Standard UL 943 The self monitoring function checks proper operation of the ground fault protection circuitry every 1 to 10 min If an...

Страница 47: ...put from the GFCI receptacle to a Panel Board Load Center where the Neutral is bonded to the Earth Ground This will trip the GFCI 2 If an extension cord is used please ensure that the cord is 2 Pole G...

Страница 48: ...e Earth Ground connection a connection that connects to the Ground Rod or to the water pipe or to another connec tion that is solidly bonded to the Earth Ground The connections must be tight against b...

Страница 49: ...au fond EXT Position de l interrupteur 8 9 1 ON OFF Control Options The unit can be switched ON OFF from a remote location using external wired ON OFF control options as shown in Fig 8 2 a b and c and...

Страница 50: ...reverse polarity 2 Use 1A fuse as shown as close to the DC source as possible ATTENTION 1 Veuillez vous assurer que la polarit de la liaison de c blage La borne positive de la source de courant contin...

Страница 51: ...1 Veuillez vous assurer que la polarit de la liaison de c blage La borne positive de la source de courant continu externe doit tre connect la borne positive marqu e sur le bornier 3 contacts 4A figur...

Страница 52: ...l be alive even when the switch is in the OFF position Hence disconnect the DC and AC sides before working on any circuits connected to the inverter ATTENTION Veuillez noter que l interrupteur ON OFF...

Страница 53: ...and the Status LED on the GFCI 5C in Fig 6 1 will be lighted Green Please see under Protections Section 10 and Troubleshooting Guide Section 11 for symp toms of abnormal operation 9 5 NO LOAD DRAW IDL...

Страница 54: ...pendra du type de charge charge r sistive ou r actif et c est le facteur de puissance facteur de puissance peut aller de 1 0 5 Veuillez noter ce qui suit Puissance active W Puissance apparente VA x Fa...

Страница 55: ...op in the battery cables and connectors The drop in the voltage at the DC input terminals of the inverter could be due to lower battery terminal voltage or due to abnormally high drop in the battery c...

Страница 56: ...ERMINALS The Positive of the battery should be connected to the Positive DC input terminal of the inverter 9 Fig 6 1 and the Negative of the battery should be connected to the Negative DC input termin...

Страница 57: ...connexions la batterie du c t d entr e veuillez assurer que les polarit s sont mises du bon c t Li le Positif de la batterie la borne Positive de l appareil et le N gatif de la batterie la borne N gat...

Страница 58: ...circuit Reduce load AC output voltage is available Buzzer alarm is sounded at no load or when load is switched on The Green LED marked POWER ON 2 Fig 6 1 is lighted Status LED on the GFCI outlet 5C F...

Страница 59: ...latched in this shut down condition and will require manual reset To reset switch OFF the power ON OFF switch 1 Fig 6 1 wait for 3 minutes and then switch ON again Before switching ON again remove the...

Страница 60: ...l to Ground bond and remove this ground fault condition Switch ON the inverter if in OFF condition Check that the Green LED marked POWER ON 2 Fig 6 1 is lighted Press Reset Button 5A Fig 6 1 on the GF...

Страница 61: ...to reset 33V SHORT CIRCUIT SHUTDOWN When output voltage drops to 80V or lower OVERLOAD SHUTDOWN At overload of 110 to 115 GROUND FAULT SHUTDOWN Through GFCI outlets 6 mA leakage OVER TEMPERATURE SHUTD...

Страница 62: ...th tin foil or wire as this may cause serious damage elsewhere in the electrical circuit or cause fire ATTENTION RISQUE D INCENDIE Ne remplacez pas un fusible de v hicule avec une taille plus grande q...

Страница 63: ...having a reasonable number of opportunities to do so Warranty service shall be performed only by the Warrantor Any attempt to remedy the defect by anyone other than the Warrantor shall render this war...

Страница 64: ...Numbers Ph 1 800 561 5885 Fax 1 888 814 5210 Local Numbers Ph 604 525 3836 Fax 604 525 5221 Website www samlexamerica com USA Shipping Warehouses Kent WA Plymouth MI Canadian Shipping Warehouse Delta...

Отзывы: