14 | SAMLEX AMERICA INC.
SECTION 6 |
Specifications
PARAMETER
SPECIFICATIONS
Electrical
Nominal Battery System Voltage
12V
Rated Charge / Discharge Current
10A
Minimum Battery Voltage to Start Controller
6V
Self Consumption
≤ 8.4mA
Temperature Compensation
18mV/°C (With built-in Temperature Sensor)
Battery Charging
NOTES: (i) Specifications are for Sealed / AGM Lead Acid Battery
(ii) All voltage specifications are at 25°C
Type of Lead Acid Battery
Sealed, AGM
Bulk Charge Current
Equal to instantaneous Short Circuit Current
Isc of the Solar Array
Absorption (Boost) Stage Voltage, “Va”
14.4V
Absorption (Boost) Stage Duration
2 Hrs
Equalization Stage Voltage, “Ve”
14.6V
Equalization Stage Duration
2 Hrs
Condition for Executing Equalization Cycle
Battery Voltage drops to 10.8V
Float Voltage, “Vf”
13.8V
Exit to Absorption (Boost) when in Float Stage
13.2V
Under Voltage Warning
12.0V (LED Battery Status Indicator Orange)
Under Voltage Warning Auto Reset
12.2V
Over Voltage Limit
≥15.5V (Charging Stops)
Over Voltage Limit Auto Reset
≤ 15.0V (Charging Resumes)
Over Voltage Disconnect Indication
16.0V
Control on Load Terminals
Low Battery Disconnect
11.1V
Low Battery Reconnect
12.6V
Environmental
Operating Temperature
-35
°
C to +55
°
C
Storage Temperature
-35
°
C to 80
°C
Humidity
≤95% Non Condensing
Ingress Protection (IP) Rating
IP-30 (Protected against ingress of objects >
2.5mm; Not protected against ingress of water)
Mechanical
Input Output Connections
Moving Cage Type, 4mm
2
/AWG#12
Compliance
Electro Magnetic Compatibility
CE Marked – Conformity with EMC Directive
2004/108/EC
Note:
Specifications are subject to change without notice.
SPECIFICATIONS OF CHARGE CONTROLLER - MSK-10A