In the rare instance of the hand held unit failing to operate, the heater can
be operated manually. Remove the batteries from the remote to ensure the
remote unit is no longer sending signals to the heater.
The heater can now be controlled using the manual settings on the side of
the heater fascia as shown below. These controls come standard with the
heater and do not incorporate a thermostat.
Page 17.
This Remote Thermostat is a room thermostat and to function correctly it
should be located in the same room as the heater within personal
comfort zone.
The thermostat is factory set with the default settings shown below and
will operate at settings indicated. If you wish to change these times or
temperatures see the Programming section later in manual.
Automatic Factory default settings
Factory default settings
Time Period Start Time Heat Temperature (°C)
Wake up. 6.00 am 20 °C
Away. 8.30 am 7 °C
Coming home. 5.00 pm 21 °C
Sleep. 10.30 pm 7 °C
The room will be maintained at set temperature during set period.
21°C
7°C
20°C
6.00AM
6.00AM
8.30AM
5.00PM
10.30PM
At any time during the automatic program period, the temperature can be
increased or decreased by pressing the “
UP
” or “
DOWN
” buttons.
To start heater.
Select “
PWR
” and “
OK
” buttons and press them together (then release).
Select Auto or Manual by pressing “
A/M
” button (then release).
The heater will only operate if the actual room temperature is lower
than the required temperature.
Manual Mode:
Press “
A/M
” Button to
select “Manual” mode.
The required temperature can be selected by using ‘
UP
’ or ‘
DOWN
’
buttons.
Room temperature is shown at top of screen.
Selected temperature shown at mid screen.
Automatic Mode
Press “
A/M”
Button to
select “Auto” mode.
Set
current
time and date. (See setting time and date later in manual.)
Page 2.
Manual operation
QUICK START GUIDE
ON/OFF button
When there is power to the heater but it
is on standby mode a red LED will blink
intermittently behind this button.
To turn heater on press the ON/OFF
button.
There will be a 5 second delay (30
second for Powerflue unit) before the
burner ignites. At this point the burner is
on low flame / low fan for 3 minutes.
During the ignition process the red LED
will glow.
The red LED will fade out after 30
seconds when the ignition process is
complete.
Pressing the heat setting buttons will set
the heater to HIGH , MEDIUM or LOW
heat.
The fan is set to a corresponding speed
for each setting.
To turn the heater off press the ON/OFF
button.
If the burner fails to ignite, wait 20
seconds and then press the ON/OFF
button.
In case of power failure, when the power
returns, wait 20 seconds for any unburnt
gas to vent and start re-ignition by
pressing the ON/OFF button.
ON / OFF
LOW
MEDIUM
HIGH