JOLLY
www.larius.com
17
REV.
01 - 09/2020 - Cod. 150165
N
•
Insert the gun clamp (
N1
).
•
Move the switch (
N2
) to the
OFF
position to stop the
equipment.
•
Reduce pressure to the minimum
(turn counterclockwise the
pressure control knob (
N3
))
.
CORRECT PROCEDURE
OF DECOMPRESSION
•
Disconnect the power supply cable (
N4
).
•
Release the gun clamp (
N1
), point the gun into the tank of
the product and press the trigger to release pressure. At the
end of the operation, insert the gun clamp.
•
Open clockwise the recirculating-safety valve (
N5
) to release
the residual pressure.
WARNING
:
If the equipment is still under pressure after
performing the operations above described be-
cause of the nozzle or the flexible hose clogged,
proceed as follows:
•
Loosen very slowly the gun nozzle.
•
Release the clamp.
•
Point the gun into the container of the product
and press the trigger to release pressure.
•
Loosen very slowly the fitting of connection
from the flexible hose to the gun.
•
Clean or replace the flexible hose and the
nozzle.
Clamp released
Clamp inserted
OFF
N1
Fig. 1N
Fig. 2N
N3
N2
Fig. 3N
N5
Fig. 2J
N4