CHANGE IN MEASURING UNITS
CHANGE IN MEASURING UNITS
The meter can be configured to use litres [L], gallons [G],
pints [P] or quarters [Q].
When making a change from one unit to another the
conversion of the quantity stored is made both in the partial
meter and in the total meter.
Setting the units
Set the partial meter mode in the meter (fig. 29). Proceed
by simultaneously pressing the buttons ON/RESET and
SELECT for 1 second (fig. 30) and release the buttons.
“Unit” is shown on the meter display.
Press the SELECT button (fig. 31) to alternately change
the units. Once the desired unit is set, press the ON/
RESET button (fig. 32) to save the configuration and
enter the normal meter mode.
If, during the unit change process 30 seconds elapse
without the meter being pressed it will change to the
OFF mode.
Fig. 29
Fig. 30
Fig. 31
Fig. 32
1"
WARNING:
to ensure that the required quantity of
fluid is released always use the same measurement
unit for a specific fluid.
The changes in units must only be carried out by
authorised employees.
Symptom
Possible cause
Solution
Blurred or unclear reading.
Batteries empty.
Replace the batteries.
The meter does not switch on.
Batteries empty.
Replace the batteries.
The meter is inaccurate.
Erroneous calibration factor.
Calibrate the meter.
A fluid with very high or very low
viscosity is being used.
Calibrate the meter.
Very high or low fluid temperature.
Calibrate the meter.
The meter is working outside its field of
application (see technical specifica-
tions).
Restore the working conditions (flow,
viscosity, temperature...) to those
required by the meter.
Reduced flow.
Dirt in the measuring chamber.
Clean the measuring chamber.
The meter does not count.
Faulty reed sensor.
Inform technical support.