SPECIFICATIONS
CAUTION! : THERE IS NO ISOLATION BETWEEN THE INPUT AND THE OUTPUT.
INPUT AND OUTPUT HAVE A COMMON NEGATIVE
Input to output isolation
Not isolated. Input and output connections have a common negative
Input voltage
20 to 32 VDC
Output voltage
13.
6
VDC ± 0.1 V
Output voltage regulation
3%
Input current at no load
< 5 mA
Output current
Continuous
12
A
Current limit *
12.5
A
*Note
: In current limit condition, the output voltage will drop if the
current drawn increases beyond the current limit value of 5.5 A
Output ripple and noise
less than 50 mV RMS
Efficiency
Approx.
92%
Operating ambient temperature -
-20 to +30
o
C (derate linearly to zero at 70º C)
Humidity
Max.
95%,
non
condensing
Protections:
-
Overload
By
current
limiting
- Over heating
Drop in output voltage
- Reverse polarity
Fuse protection,
10
A
- Over voltage
Varistor (also protects against load dump)
Input side fuse
10
A (inside the unit)
Safety and EMC Standards:
-
Emission
EN50081-1
-
Immunity EN50082-1
- Automotive directive
95/
54
/
CE
Input / output connections
Terminal Block - 6.3 mm male flat tab, quick connect
Weight
0.
6
lbs / .
25
Kg
Dimensions (H x W x D)
1.9” x 3.
9
” x 2.7” / 49 x 88 x
9
8 mm
Warranty
2
years
NOTE: Specifications are subject to change without notice
Samlex America Inc.
110-17 Fawcett Road
Coquitlam BC Canada V3K 6V2
Telephone: (604) 525-3836
SDC
12
-
May 2008