Page 8
4.1
Ensure that the power ON/OFF switch is turned off.
4.2
Place the inverter in a cool & ventilated space. Ensure
that there is at least 10cm of open space around the
inverter. Do not block the openings on the inlet side of the
cooling fan and the vent holes.
4.3
Use #6 AWG red and black color coded cables to
connect the inverter to the battery. The red wire is positive
(+) and the black wire is negative (-). Connect the red wire
to the
RED
(+) terminal of the inverter and the black wire
to the
WHITE
(-) terminal of the inverter. Now connect the
black wire to the negative (-) terminal of the battery and
then the red wire to the positive (+) terminal of the bat-
tery.
A spark may be observed when connecting the
positive wire to the battery (+) due to charging of
capacitors inside the inverter. This is normal.
4.4
Ground the inverter using the Grounding Lug at the
rear of the unit.