Installation & Handling

Please read this manual before operating your 

ACR-160 Automatic Charge Isolator
Description

The ACR-160 microprocessor controlled battery isolator 

is used in starter and auxiliary battery systems like on 

boats, RV, service vans. It supervises the starter state 

of charge and, therefore, avoids starting problems. 

The ACR-160 can also be used as a voltage dependent 

switch. The working principle is the following: 

-  The ACR-160 lets the starter battery be recharged by 

the alternator until a voltage of 13.2V (26.4V) during 

at least 7 seconds is reached. Then the two batteries 

are put in parallel by the contact of the relay.

-  The secondary users are normally connected to the 

auxiliary battery. The relay opens when the batteries 

voltage reaches 12.8V (25.6V) during at least 60 sec-

onds. This way the starter battery remains charged. If 

a battery charger is connected to the auxiliary battery 

and this battery reaches a voltage of 13.2V (26.4V) 

during at least 7 seconds, the relay closes and charges 

at the same time the starter battery. This is an ad-

vantage if the vehicle remains stationary over a long 

period of time. If the battery charger is disconnected 

and the battery voltage reaches 12.8V (25.6V) during 

at least 60 seconds, then the ACR-160 separates again 

the two batteries.

Start Assistance

The ACR-160 has an additional connection enabling an 

assistance to the starting. If the connection STATUS is 

connected to the starter contact, the ACR-160 contact 

closes and this way the 2 batteries contribute to the 

engine start. Caution: When this function is used. 

Very high currents may go through the relay contact 

by the start of bigger engines. these high currents may 

damage the contact of the aCR-160 if they exceed its 

nominal current.

Voltage Dependent Switch

In some cases, it is needed to have a powerful DC source 

supply but only when the engine is running. The ACR-

160 allows also this kind of installations.
It is sufficient to simply connect "+" of the starter bat-

tery to the connection A1, the system ground to the 

connection MINUS and the positive of the equipment to 

be supplied to the connection A2. When the engine runs 

and a voltage of 13.2V (26.4V) during at least 7 seconds 

is reached, the equipment is then powered through the 

contact of the ACR-160.

Remote Indication of Relay ON Condition

Connect external LED as shown.

Disable Relay Permanently

Use external switch as shown.

Protection Against Over Voltages

The ACR-160 has also a function enabling to  

protect the battery and the appliances that are  

connected to it against an over voltage generated,  

for instance, by a defective alternator. As soon as a  

voltage higher than 16V (32V) is detected, the  

contact of the ACR-160 opens immediately.

Installation

To implement the function «start assistance», a fuse 

protected connection has to be carried out between the 

connection STATUS and the contact of the starter con-

tact. a short-circuit between the positive and negative 

of the batteries can damage your system. Make sure 

that the connections are properly done!

Technical Specifications

Supply ....................... Automatic detection 12/24V
Max. current .....................................................160A
Peak current .......................... 480A for 250 millisec
Battery connection ............................................ M8
other connections .......................... Faston 6,3 mm
Cable cross section ...................................... 50mmq
Consumption oFF ..........12V=1.8mA / 24V=2.0mA 
Consumption oN .........12V=340mA / 24V=170mA 
Minimum charge time ........................... 60 seconds
Fast opening:
< 11.8V (12V) / 23.6 (24V) after 4 seconds

Connections

A1: Positive terminal of the starter battery
A2: Positive terminal of the auxiliary battery

(If the function «voltage dependent switch»

is needed, connect the equipment positive here).
STATUS: 

1. Contact to "+", relay is closed (Start assistance)

2. No connection on STATUS , normal operation

3. Contact to "", relay remains closed
MINUS: Negative terminal  

(Caution - this connection must always  

remain connected via a fuse of 1a)
LED: Connection for remote indication  

for status of ACR-160)

+

+12VDC (+24VDC)

To the starter contact

(optional, see installation)

STARTER

BATTERY

1A

+

ALTERNATOR

200A

1A

1A

AWG 

#16

A1

A2

LED

STATUS

MINUS

+

AUXILIARY

BATTERY

200A

1A

+ –

EXTERNAL

CHARGER

External LED 

to indicate 

activation

of relay

External 

switch to

disable 

the relay

permanently

CAUTION!

Wire sizes to be based on

maximum current and 2% 

voltage drop.
Fuses to match wire sizes.

AWG 

#16

AWG 

#16

AWG 

#16

ACR-160