Remote Control Manual
| 1
900-RC
INSTRUCTIONAL MANUAL
ON / OFF
MODEL 900-RC
REMOTE SWITCH
FRONT VIEW
SIDE VIEW
U phase UO phase I phase
POWER
32.25 mm
64.5 mm
6 mm
6 mm
4 mm
Diameter
4 mm
Diameter
1
5
4
3
2
27.7 mm
50.7 mm
108.7 mm
96.7 mm
30.3 mm
25.4 mm
6
Legend:
1 ON/OFF key
2 Green LED - "Power"
3 Red LED - I phase
4 Yellow LED - Uo phase
5 Green LED - U phase
6 8P8C Modular Jack for cable connection
7 8P8C Cable, Straight, 10 Metres
7
DESCRIPTION, FEATURES & APPLICATIONS
The Samlex America 900-RC is a wired Remote Control that is compatible with the
following series of Battery Chargers:
-
SEC-1245A, SEC-1260A, SEC-1280A, SEC-1250UL, SEC-1280UL
-
SEC-2425A, SEC-2440A, SEC-2425UL, SEC-2440UL
It is used to switch ON and witch OFF the charger from a remote location. It also
displays the operational status and the charging stages using colored LEDs.
It is provided with 10M / 33ft of RJ-45 (8P8C), Straight cable set.
INSTALLATION & OPERATION
Installation
Please refer to Fig 1.1 for dimensional drawing.
It can be flush mounted on a wall or a panel by making a suitable cut out to
accomodate the rojection in the back.
Connect one end of the 10M / 33ft of RJ-45 (8P8C), Straight cable set to the jack (6)
at the back of the Remote panel and the other end to the Remote Control Jack on
the charger. Ensure that the connection is firm and the tab on the plug securely locks
in the jack.
Operation
Please refer to Fig 1. Please also refer to the manual of the charger for associated
details on the charging stages.
Switch on the AC power to the charger first with the help of the Power ON/OFF
switch on the charger.
The output of the charger can now be switched OFF/ON by pressing the ON/OFF Key (1).
When the charger is in ON condition, the Green LED marked "Power" (2) will be
lighted.
Depending upon the charging stage of the charger, the charging status will be
displayed as follows:
-
Bulk Charge Stage or "I Phase": Red LED marked "I phase" (3) will be lighted
-
Absorption Stage or "Uo Phase": Yellow LED marked "Uo Phase" (4) will be lighted
-
Float Stage or "U Phase": Green LED marked "U Phase" will be lighted
Indications Under Abnormal Conditions
An abnormal operation of the charger might occur with the following symptoms:
-
On the Charger:
No output and fan is ON continuosly
-
On the Remote:
Red LED marked "I phase" (3) and Green LED marked
"Power" (2) are lighted.
These symptoms may indicate the following reasons for abnormal operation of the
charger: (Please read the charger manual for more details)
-
The DC side output fuse is blown
-
The battery / DC load is shorted
-
Shut down due to high temperature
-
AC input has been set to 230 VAC and is being operated at 120 VAC
DIMENSIONS & LAYOUT
SPECIFICATIONS
MODEL No. OF COMPATIBLE
BATTERY CHARGERS
SEC-1245A, SEC-1260A, SEC-1280A,
SEC-1250UL, SEC-1280UL, SEC-2425A,
SEC-2440A, SEC-2425UL, SEC-2440UL
CABLE SET
RJ-45 (8P8C), Straight
Length = 10M / 33ft
OPERATING TEMPERATURE RANGE
0 to 40
°
C
DIMENSIONS (W x D x H)
64.5 x 25.4 x 108.7 mm
2.54 x 1.0 x 4.28 in
WEIGHT
0.36 kg / 0.8 lb
NOTE: Specifications are subject to change without notice
Head Office
103 - 4268 Lozells Avenue
Burnaby, BC V5A 0C6 Canada
Toll Free Numbers
Ph: 1-800-561-5885
Fax: 1-888-814-5210
Local Numbers
Ph: 604-525-3836
Fax: 604-525-5221