background image

3

SR4_5-6_0KTL-G3-IG_11_AA

Life threatening voltages are 

processed inside the inverter.

Hazardous situations that can lead to 

death or serious injuries are indicated 

with the “

WARNING

” symbol (1) on 

the left.

Hazardous situations that can result in 

damage of the inverter are indicated 

with the “

CAUTION

” symbol (2) on the 

left.

Countermeasures that must 

be taken in order to avoid the 

hazardous situation are indicated with 

an arrow:

 

Î

“This is an example how to avoid a 

hazardous situation.” 

Safety Symbols

1

2

该逆变器内部存在危险电压

左侧“警告(WARNING)”标志(1

),用于警示潜在的危险情形,若不避

免,可能会导致人员死亡或严重的人身

伤害。

左侧“注意(CAUTION)”标志(2

)旨在说明可以导致逆变器破损的危险

情况。

为了避免危险情况,请务必按

照箭头图标所示的方法进行处

理。

 

Î

“此例说明如何避免危险情况” 

安装图标说明

EN

ZH

Содержание SolarRiver 4500TL-G3

Страница 1: ...1 SR4_5 6_0KTL G3 IG_11_AA 1 SolarRiver 4500TL G3 SolarRiver 5300TL G3 SolarRiver 5600TL G3 SolarRiver 6000TL G3 A...

Страница 2: ...2 SR4_5 6_0KTL G3 IG_11_AA...

Страница 3: ...Inverter Function 9 Labels and Markings on the Inverter 10 Unpacking 11 Mounting the Inverter 13 AC and DC Connection 16 Connection of the WIFI GPRS Monitoring Module 20 Starting the Inverter 21 Comm...

Страница 4: ...ge of the installation Supplier Company the product was purchased from Inverter PV inverter described in this installation guide About this Installation Guide EN SolarRiver 4500TL G3 Max DC Power 4500...

Страница 5: ...ted with the WARNING symbol 1 on the left Hazardous situations that can result in damage of the inverter are indicated with the CAUTION symbol 2 on the left Countermeasures that must be taken in order...

Страница 6: ...er when you have questions 3 Wear safety shoes when lifting and transporting 4 Disassembling the inverter is forbidden WARNING Danger of electric shock and fire Never modify the inverter unless explic...

Страница 7: ...utomatically disconnects 4 from the grid The inverter automatically reconnects when the grid is restored The inverter can only be used for DC power from PV generators 5 CAUTION Risk of damaging the in...

Страница 8: ...when exposed to sunlight 2 The inverter is not equipped with an internal isolation transformer 3 Local regulations and standards can require that an isolation transformer is additionally installed Co...

Страница 9: ...short circuit current of the PV strings is less than the maximum input current of the inverter 3 Fix a manual DC breaker between the PV modules and the inverter Ur 600Vdc Ir 40A 4 Keep the DC breaker...

Страница 10: ...nnect at all the connecting time 4 Choose an appropriate breaker according to the AC output specification of the inverter 5 The inverter is equipped with an integrated RCMU Type B tested according to...

Страница 11: ...ation monitoring 2 DC side disconnection switch 3 Status LEDs 4 AC side disconnection relay 5 Grid monitoring 6 AC side surge voltage protection 7 GPRS 8 WIFI Note The inverter is equipped with either...

Страница 12: ...8 DC connection area 9 PE connections 10 DC Switch 11 WIFI GPRS module 12 DRM 0 13 AC plug Periodic Inspection Check if all markings and safety symbols are clearly visible on the inverter Replace if...

Страница 13: ...e packing list are included The scope of delivery is listed on the following page 4 Check all items for visible damages 5 Contact your supplier when items are missing or the inverter is damaged Do not...

Страница 14: ...wing tools are required for the installation of the inverter 1 Cable stripping tool for cables e g PV AZM 2 Drill 3 Multimeter 4 Pencil 5 Screwdriver 6 Spanner 7 Hammer 8 Level Required Tools EN 1 PV...

Страница 15: ...Proceed as follows 1 Drilling two horizontal holes on the wall with a diameter of 8mm aiguille 2 Assemble expansion bolts screw exposed wall 4 8mm 3 Hang the inverter on the screw 4 Tighten the bolts...

Страница 16: ...SR4_5 6_0KTL G3 IG_11_AA 14 357 mm 297 mm 166 mm 10 kg 275 mm min 30 cm min 30 cm min 30 cm min 30 cm...

Страница 17: ...15 SR4_5 6_0KTL G3 IG_11_AA 45 C 20 C 95 45 C 20 C 95 25...

Страница 18: ...ircuit breaker 2 WARNING Risk of fire Do not connect any consumers to the AC line 3 Recommendation Keep cable losses below 1 Keep impedance below 0 2 Ohm 4 Observe values for wire sizes 5 In France Us...

Страница 19: ...emove swivel nut and shove swivel nut over cable 6 Attach wires to AC terminal Green yellow wire PE Ground Blue wire N Neutral Brown wire L Line 7 Push plug into sleeve Tighten swivel nut 8 In France...

Страница 20: ...uipped with two separate MPP trackers 4 The DC ports can be connected Install diodes in order to avoid reverse currents 5 Cover PV modules when working on the DC connection 6 WARNING Risk of electric...

Страница 21: ...module array voltage Proceed as follows 1 Strip cable 2 Unscrew plug 3 Put swivel nut on cable 4 Crimp cable on plug contact 5 Insert plug contact in plug Pull on contact in order to check that the c...

Страница 22: ...dules or AC Grid 1 Insert the WiFi GPRS module into the corresponding connector at the bottom of the inverter 2 Tighten up the screws Ensure that the WiFi GPRS module and inverter are connected secure...

Страница 23: ...DC plugs are connected Proceed as follows for starting 1 Connect AC plug 2 Connect DC plugs 3 Turn DC switch to ON 4 Activate AC power The inverter starts operation If the inverter works for the first...

Страница 24: ...nect the WiFi hotspot of the inverter Samil_xxxxxxxxxx Wi Fi 10 28 60 Wi Fi Samil_xxxxxxxxxx CMCC WiFi 123 Samil_xxxxxxxxxx CMCC WiFi 123 xxxxxxxxxx is the 10 bit series number of the inverter Click t...

Страница 25: ...WiFi SSID None CMCC WiFi Samilportal APP LED WiFi Samil_xxxxxxxxxx Wi Fi 10 28 60 Wi Fi Samil_xxxxxxxxxx CMCC WiFi 123 Samil_xxxxxxxxxx CMCC WiFi 123 xxxxxxxxxx 10 SamilPortal APP APP WiFi SSID CZ EN...

Страница 26: ...Blue light flashing alternately AC power fault No AC power Grid frequency AC voltage over range and etc Please resort to the electrician Red light and Green light flashing alternately FAN fault Pleas...

Страница 27: ...25 SR4_5 6_0KTL G3 IG_11_AA ZH LED 1 WIFI APP 2 GPRS 3 FAN RTC APP ISO GFCI PV...

Страница 28: ...eside the inverter can view the monitoring data and set the parameters via SamilPortal APP local mode 2 Remote Monitoring Mode The inverter supports remote monitoring by connecting the GPRS module or...

Страница 29: ...tatus and power generation data after entering the Running data History data Events list and System info interface User can set the inverter parameters after entering the setting interface User can up...

Страница 30: ...Fi module are connected securely The module can only be installed as described on page 21 Scan the series number Password Click the SamilPortal APP Select Local mode in the mode select interface and e...

Страница 31: ...29 SR4_5 6_0KTL G3 IG_11_AA SR12345678 123456 1234 GPRS WIFi P21 SamilPortal APP APP ZH...

Страница 32: ...MPP voltage range Min input voltage initial input voltage Max input current Number of independent MPP inputs strings per MPP input Output AC Rated power cos 1 Max apparent AC power Max output current...

Страница 33: ...125 V 560 V I II DC III AC 25 C 60 C 1 W IP65 95 MC4 LED APP 3 5 LCD DC MPPT MPP MPPT MPPT AC cos 1 IEC 62103 IEC 60664 1 IEC 60529 DC AC WiFi GPRS 5 10 15 20 SolarRiver 5300TL G3 4600W SolarRiver 53...

Страница 34: ...32 SR4_5 6_0KTL G3 IG_11_AA...

Страница 35: ...System Details Inverter Model Inverter Serial Number PV Module Type Number of Strings Modules per String Signature Date Fault Details Fault Code Fault Description Signature Date For Office Use Remark...

Страница 36: ......

Страница 37: ......

Страница 38: ...36 SR4_5 6_0KTL G3 IG_11_AA SR4_5 6_0KTL G3 IG_11_AA Art No 614 04301 01...

Отзывы: