Revised A
65
6301
7. Cleaning procedures
At the end of each shift or as required by plant practices, activate the purge cycle.
• Stop and shut down the system.
• Clean the atomizer using dump solvent rag.
CAUTION : On no account should the atomizer or any of its component be sprayed with solvent
or high/low pressure water.
SAMES Technologies does not recommend the use of covers.
Although, if the plant chooses to protect atomizers with covers, do not use “anti-static quality” plastic films
as these are conductive, and can short-circuit the high voltage.
A thin layer of dielectric grease (pure vaseline P/N # H1GMIN017) applied before covering the parts,
facilitates removal of the cover.
WARNING : Always wear safety glasses or goggles
Always wear rubber gloves when handling solvent
Work in well ventilated area when handling solvent.
WARNING : Do not soak the turbine in solvent or use a solvent spray gun. Use a rag and soft
bristle brush using an approved cleaning solution.
Procedure
Components
Frequency
A
Tightening ring, outer ring, outer bellcup surface
8 hours
B
Bellcup, inner and outer ring, outer injector surface,
outer bellcup surface, outer clip surface
120 hours
C
Clip
480 hours