Revision index: E - May 14
th
, 1998
- 9 -
Code : RT 6015
3. COMMISSIONING
3.1. PREPARING THE SPRAY GUN
(refer to Fig.4)
∗
Fasten the adapter flange [5] onto the bracket used to support the spray gun.
∗
Fasten the socket [1] of the electrical power supply cable onto the fixed flange [2]. Check socket orientation (contact
marks in front of plug contacts of plug [3] installed in the mobile flange [4].
∗
Connect the pneumatic and powder feed pipes onto the fixed flange [2]. Fasten the fixed flange onto the adapter flange
[5].
3.2. OPERATION AND SETTINGS
The SRV 028-Twin 60° powder spray gun should be installed 150 to 300 mm from the part to be painted.
Powder fluidizing, powder flow and voltage adjustments are described in the instructions manual of the GND 504-B
control unit.
CAUTION :
Current consumption with the SRV 028-Twin 60° spray gun should never exceed 30 µA per gun
(i.e. 60 µA for two guns) during spraying. Higher current consumption would result in fouling of
the electrode and will cause loss of efficiency of the spray gun.