1.4.1. Installation Rules
PPH 707 CHEM ICWB M TI
:
WARNING : All the conductive parts must be connected to the high voltage potential (metallic
fittings of the Moduclean, gear pump,etc...).
Conductive coating products
1
Control module GNM 200
2
Low voltage connection
3
High voltage unit UHT 287 EEx e
4
High voltage cable connecting insulating table to UHT 287 and to PPH 707 CHEM ICWB M TI
5
Supplies of coating products and rinsing products insulated to the ground potential
6
Dump return line insulated to the ground potential
7
Short circuiter
8
-
9
Safety distance (area around the atomizer head from the parts with high voltage, outer cover,
bell cup, etc...)
x
S
A
1
2
5
DES03662
S: rinsing product
A: Air supply
1: Product 1 supply
2: Product 2 supply
Standard Dump
Protection enclosure if system
isolated out of paint booth
Nota
: A connection to the ground
of the shielding of the connecting
cable between the HVU and the in-
sulating table at exit of ”cage” is
imperative (