53
Member of EXEL group
6.4.8. Procedure D1:
Replacement of the electropneumatic coupling
•
Step 1
:
Separate the barrel from the handle.
•
Step 2: Handle base
Unscrew the air nipple using a 6mm allen key.
Replace the seals every 12 months.
•
Step 3
:
Undo both K35 x 14 screws with a
2mm Phillip's screwdriver. Change the fibre
washers each time the screws are removed.
•
Step 4
:
Lift the base to access the handle
base seal. This seal should be replaced every
12 months.
•
Step 5
:
Push the electrical connector to
release it and remove from the base.
Replace the seal of the connector every 12
months.
•
Step 6: Replacement of the base:
unscrew
the screw of the ground wire using a 0 Phillip's
screwdriver, withdraw it and replace it.
To reassemble,
follow the steps in reverse order.
Insert the connector pin back into the base
foolproofing slot.
Coat the air nipple seals with dielectric lubricant.
Tighten the air nipple to 1.5 N.m torque.
Tighten the two K35 x 14 screws to 1.3 N.m torque.