Index revision : A
19
7159
6.2. Hopper version
•
Step
1
: Release the ground wire lug atta-
ched to the cart and connect it to the hop-
per.
Then connect the fluidizing hose to the
hopper.
•
Step
2
: Equip the plunger tube with the CS
130 pump, then place the assembly in one
of the holes in the hopper. Connect the 2
hoses on the powder pump blue to blue,
red to red.
•
Step
3
: Connect the 5 m ground cable to
an electrically grounded part of the pow-
dering booth.
•
Step
4
: Connect the Inobox power supply.
•
Step
5
: Connect the powder supply hose from the gun to the CS 130 pump and connect
the electrode blowing hose on the Inobox controll module side and on the gun side.
•
Etape 6
:
Connect the plastic fume exhaust hose to the tank on one side and to the booth
on the other.
Note: The connection point on the booth must always be positioned above the hopper
to prevent the plastic sheath from "sinking" and to limit the clogging of the sheath.
Regularly check the inside of the sheath to prevent clogging.
The Inocart H cart is ready to start the powder application.
Step 1
Step 2
Step 3