Index revision : A
20
7143
Place the booth bottom box (1) on a floor with a resistance higher than 400 kN / m2 and it must
be strictly horizontal.
First adjust the four outer support feet (2) and then unscrew the other support feet until they are
in contact with the floor.
WARNING : It is imperative to correctly adjust the height of the box (580 mm from the floor) so
that the suction duct does not stress the booth during installation and operation.
DES07492
2