Indice de révision : G
8
6102
•
P5
= 1 triggering called «external». «Discrete I/o» (dry contact, 12 or 24 V depending on type of
connection,
3.2.1.4. Display of the last 10 faults
The 4
key permits one to go to the next screen. On the first line, one can read the last fault. Pressure
on keys 2
and 3
permits one to scroll the 9 other faults upwards or downwards. The fault carrying
the highest number is the most recent. To initiate the list again, press key 5
.
WARNING : An interruption in the power supply to the controller erase the list of faults.
3.2.1.5. Display of Effective Voltage and Current when Trigger is Activated
When the generator is active and the high voltage is triggered the screen will display for example 50 Kv
a 45 µA current draw.
3.2.2. Calibrating menu
WARNING : This section is for the customer's trained personnel. Entry into the calibrating menu
puts the HV out of service.
If no key is pressed for more than one minute, the user mode is automatically restored and the
parameters are stored.
Vc
Voltage set point
Vm
Voltage Return
1
Trigger
Vc
Voltage set point
Vm
Voltage Return