Index revision : A
20
7161
8.2.2. Procedure B: Cleaning of the injection air check valve
• Switch off the high-voltage supply,
•
Step 1
: Switch off the air supply
•
Step 2
: Disconnect the hose upstream of
the valve by pressing the green ring, then
downstream on the red ring.
•
Step 3
: Then clean the valve with compressed air. If necessary, clean the tank injector.
8.2.3. Procedure C: Dump of tank
8.2.3.1. Procedure 1
•
Step 1
: Disconnect the air supplies on the tank.
•
Step 2
: Remove the cover by unscrewing the clamps.
•
Step 3
: Disconnect the ground wire from the tank.
•
Step 4
: Unscrew the 3 knobs that secure the tank to the tank holder. Take out the tank,
taking care not to shock the vibrator.
•
Step 5
: Empty the tank into the booth and clean the remaining powder with compressed
air.
8.2.3.2. Procedure 2
•
Step 1
: Disconnect the injection air supply to the pressure tank.
•
Step 2
: Place a recovery box under the pressure tank.
•
Step 3
: Unscrew the threaded ring and pull the injector/ejector assembly upwards. The
powder then falls into the tray. Clean the remaining powder with compressed air.