Samcon RoughCam IPM2036 Скачать руководство пользователя страница 22

 
 
 

 
 

Doc.-ID: 220815-PT10BA-ES-RoughCam IPM2036_en_rev.00.docx, Page 22 of 28 

To open the stainless-steel housing (T11 VA2.1.x.x) of RoughCam IPM2036, loosen the 
eight cylinder-head hexagon screws (DIN 912/ ISO 4762) together with their spring rings 
(DIN 127A) on the rear side of the cable and power supply flange (see Figure 6-3). Cau-
tion:  do  not  touch  the  screw  threads  with  your  skin  or  clothes!  On  the  threads,  there  is 
LOCTITE® 243™ (chemical basis is dimethacrylate ester) applied to prevent the bolted 
connection  from  unintentional  loosening  because  of  impacts  and  vibrations  and  to  seal 
them tightly. It is not permitted for the customer to open the front-side sight glass flange! 
There is no need of such an action. 
 
 

 

Figure 6-3 Opening the RoughCam IPM2036 (similar illustration) 

 
Carefully  pull  out  the  cable  and  supply  flange  to  the  rear,  as  straight  as  possible.  Be-
cause of negative pressure, it may be difficult to remove the flange.  
Attention: The mounting adapter with the housing’s PTC heater, camera module and op-
tics,  as  well  as  the  temperature  control,  and  (if  applicable)  auxiliary  relays  and  terminal 
block are fixed on the cable and supply flange. Dealing with these components, too, you 
have to work very carefully and precisely in order to avoid canting and damage to the in-
built  components!  Caution:  do  not  touch  the  cylindrical  fit  surface  with  your  skin  or 
clothes! On the surface, there is oil lubricating paste to protect the surface against fretting 
corrosion and mechanical stresses. 

 

When you open the housing, pay attention that you do not damage the GYLON® flat seal 
(blue, RAL5012) and do not make it dirty! The flat gasket is loosely attached to the cable 
and power supply flange. It is fixed only by the bolted connections! 
 

Содержание RoughCam IPM2036

Страница 1: ...RoughCam IPM2036 User Manual...

Страница 2: ...n 9 2 6 3 Illumination tests 10 3 Safety Instructions 11 4 Installation 11 5 Electrical connection 13 5 1 Potential equalization 13 5 2 Connection work at the device terminal box and fuses 14 5 2 1 Fu...

Страница 3: ...nment of terminal box ExTB 2 3 ASKD02 T 16 Figure 5 6 Sample circuit of terminal box ExTB 2 16 Figure 5 7 Connection to the terminal box 17 Table 5 4 Wire assignment of terminal box ExTB 2 SKD05 HT 18...

Страница 4: ...ed but also the chemical resistance is maximized To see other approvals please visit our website at www samcon eu en When designing the RoughCam IPM2036 we attached a very high importance to me chanic...

Страница 5: ...g with cool Jacket for extreme high temperatures Tamb 120 C 5 005 N Length of the connection line in meter at delivery 5m is the standard cable length max cable length is 005 100 m 005 N Non armoured...

Страница 6: ...nce voltage 48 V DC 44 54 V DC Max power consumption 25 5 W 30 W from the PSD Typical power consumption 12 95 W 2 3 Connection cable Description Data transfer and power supply of the camera module com...

Страница 7: ..._Datasheet pdf Figure 2 2 Sectional view of ASKD02 T 2 3 2 Connection cable for model with cool Jacket SKD05 HT Description Data transfer and power supply of the camera module compliant with DIN EN 60...

Страница 8: ...t centroid 850 nm enable high contrast black and white camera images in the dark and under difficult lighting conditions max distance in complete darkness 2m otherwise typical range depends on lightin...

Страница 9: ...he camera is in night mode Acti vate Allow IR illumination and Synchronize IR illumination 4 Tip Set the switch to night mode when it is brighter Image remains sharper as there is less low light noise...

Страница 10: ...llumination can only be used up to a maximum object distance of 2 0 m In addition the quality of the image is strongly influenced by the resulting reflections and the object to be observed is no longe...

Страница 11: ...rules of technology shall prevail Before mounting the camera thoroughly check it for any transport damage especially on the housing and cable Instal lation electrical connection and the first start mu...

Страница 12: ...https www samcon eu en products roughcam roughcam ipm2036 Optional mounting accessories Wall bracket WMB WALL MOUNT WMB VA2 1 2 2 Wall bracket for cameras of the T10 VA2 1 Series Suitable for hanging...

Страница 13: ...r 60 meters models L HH and can be individually specified by the client The user is NOT authorised to do electrical connection procedures inside the enclosure 5 1 Potential equalization Figure 5 1 Rou...

Страница 14: ...95 W Power supply for the camera PoE Voltage supply PoE IEEE 802 3af 802 3at type 1 class 3 Reference voltage 48 V DC 44 54 V DC Maximum power consumption 12 95 W Typical power consumption 5 0 W The f...

Страница 15: ...xecuted in accordance with the standard EIA TIA 568B as follows Camera T568B Colour SKD01 T IEC60757 Terminal Box Cross sectional surface Comment Tx WH OG 1 0 32 mm2 Solid conductor Tx OG 2 0 32 mm2 S...

Страница 16: ...mm2 Flex Tx WH OG 1 0 26 mm2 Solid conductor Tx OG 2 0 26 mm2 Solid conductor Rx WH GN 3 0 26 mm2 Solid conductor Rx GN 4 0 26 mm2 Solid conductor PoE 48 VDC WH BU 5 0 26 mm2 Solid conductor PoE 48 VD...

Страница 17: ...s Attention Bring the twisted pair composite up to about 10 mm close to the ter minals in order to ensure interference immunity Attention Use only terminals approved by SAMCON Attention Finally check...

Страница 18: ...m2 Solid conductor Rx GN 4 0 14 mm2 Solid conductor PoE 48 VDC WH BU 5 0 14 mm2 Solid conductor PoE 48 VDC BU 6 0 14 mm2 Solid conductor PoE GND WH BN 7 0 14 mm2 Solid conductor PoE GND BN 8 0 14 mm2...

Страница 19: ...e supplied with power hence there is no power ON priority which has to be observed Attention Use appropriate RJ45 plugs Check the cable shielding cross section and the outside diameter Attention It is...

Страница 20: ...rform all tests as indicated by the na tional regulations Furthermore check the correct function and instal lation of the device in accordance with this User Manual and other ap plicable regulations A...

Страница 21: ...epare your work carefully and in accordance with the relevant regulations 6 2 Opening the housing If the RoughCam IPM2036 is equipped with a weather protection roof this has to be re moved prior to st...

Страница 22: ...ation Carefully pull out the cable and supply flange to the rear as straight as possible Be cause of negative pressure it may be difficult to remove the flange Attention The mounting adapter with the...

Страница 23: ...yed and deleted via the web interface They are also availa ble in a download list Moreover the videos available in the memory card can also be accessed via FTP server in the network If the memory card...

Страница 24: ...system etc it may be necessary to re install the current firmware or to install an update see Chapter 7 6 5 Closing of the pressure resistant housing For closing the housing proceed in reverse order...

Страница 25: ...particularly in surroundings with fluorescent tubes In such a case the applicable settings have to be carried out inside the menu System Options Advanced Plain Config User root Password root 7 1 Brows...

Страница 26: ...Figure 7 1 MAC address and serial number for clear device identification are also detected and displayed Figure 7 1 Axis IP Utility 7 3 Password Identification The following user name is set at the f...

Страница 27: ...Document is subject to alterations and additions 10 Drawings 3D models certificates further documentation All drawings 3D models certificates and other information are available in the download area o...

Страница 28: ...Schillerstrasse 17 35102 Lohra Altenvers Germany www samcon eu info samcon eu Phone 49 6426 9231 0 fax 31...