Equipotential bonding/Grounding
Fig. 5-1 ExCam XPT Q6055 equipotential bonding
Equipotential bonding/grounding of the camera body is absolutely necessary, in order to
avoid static charges and formation of sparks. For this purpose, a screw terminal is pro-
vided at the rear side, at the bottom (right) (see Figure 5.1). The cross-section of the
equipotential bonding should comply with the National Ground Rules (at least 4 mm
2
).
Wiring table:
Potential
Colour (IEC 60757)
Cross-sec-
tion
Comment
PA
GN/YE
4 mm
2
(rigid)
-