Samcon ExCam IPP5635 Скачать руководство пользователя страница 4

 
 
 

 
 

Doc.-ID: 160720-PT08BA-SS-ExCam IPP5635_en_rev.00.docx, page  4 of  24 

Introduction 

 
The ExCam IPP5635 is a high performance IP dome camera of the latest generation with 
a 2 megapixel resolution of 1920 x 1080p pixel. It is certified according to ATEX, IECEx, 
and EAC-Ex.  
 
The dome camera has a continuous 360° pan and a 180° tilt function; the adjustment of 
the picture is done automatically. A special feature is the high speed and precession with 
which the pan as well as the tilt functions is carried out. 
 
The ExCam Series is certified according the European ATEX directive as well as to the 
international IECEx directive. The ex-protective housing is suitable for the usage within 
the Ex zones 1, 2, 21, and 22 including the gas group IIB and the dust group IIIC. It is 
also certified according to EAC-Ex. 
 
During the design of the ExCam IPP5635, the main focus was put on security as well as 
on mechanical precision and high-quality stainless steel. In addition, the modular design 
allows, for example, a connection via FOC. 
 
 
 

 

Содержание ExCam IPP5635

Страница 1: ...ExCam IPP5635 User manual...

Страница 2: ...4 Illustration of the model key 8 5 Commissioning 10 5 1 Step 1 Installation 10 5 2 Step 2 Electrical connection 10 5 2 1 Potential equalization 11 5 2 2 Connection and protection 12 5 2 3 Tests prio...

Страница 3: ...13 Figure 5 5 ExCam IPP5635 T08 TNXCD B XXX P L L 13 Table 5 2 Pin assignment SKDxx and plug contact RJ45 15 Figure 5 6 RJ45 Contact assignment 15 Figure 5 7 SKDxx Pin assignment 15 Table 5 3 Pin assi...

Страница 4: ...the high speed and precession with which the pan as well as the tilt functions is carried out The ExCam Series is certified according the European ATEX directive as well as to the international IECEx...

Страница 5: ...temperature EX 40 C 60 C Ambient temperature EX 1 50 C 50 C T6 Noticed body T V Rheinland number 0035 EU Type Examination T V 14 ATEX 7539 X IECEx TUR 14 0026X Test protocol ATEX 557 Ex 539 00 14 Tes...

Страница 6: ...aracteristics PUR halogen free flame retardant UV resistant chemical resistance shielded Interface P version RJ 45 EIA TIA 568B 10BASE T 100BASE TX PoE K version 8x single pin twisted pair solid condu...

Страница 7: ...l EN 60529 IEC 529 IP 68 Test conditions 24 h 3 m water column at 5 C An additional mechanical protection against water jets is recommended Housing material Stainless steel MNo 1 4404 X2CrNiMo17 12 2...

Страница 8: ...D B 005 P N ExCam IPP5635 T08 TNXCD B 005 K L T08 TNXCD B 005 P L ExCam IPP5635 T08 TNXCD B 005 K LL T08 TNXCD B 005 P LL Table 4 1 Model key 1 ExCam IPP5635 Functional camera description of the ExCam...

Страница 9: ...440p2 x 2 5 mm2 Cu litz wire with ferule sheath about 10 cm stripped and furnished with bend relief shrink tubing P Plug termination optional SKDxx RJ 45 network plug heavy duty AWG 26 22 Pin assignm...

Страница 10: ...essories as well as safety guidelines are described in the EX installation manual of the ExCam se ries 5 2 Step 2 Electrical connection Attention The electrical connection of the equipment must be exe...

Страница 11: ...mera s flameproof enclosure done by the user is prohibited Depending on the model option the ending of the camera s cable connection is either stripped to the blank Cu conductors or furnished with a p...

Страница 12: ...Doc ID 160720 PT08BA SS ExCam IPP5635_en_rev 00 docx page 12 of 24 5 2 2 Connection and protection Figure 5 2 ExCam IPP5635 T08 TNXCD B XXX K N Figure 5 3 ExCam IPP5635 T08 TNXCD B XXX P N...

Страница 13: ...Doc ID 160720 PT08BA SS ExCam IPP5635_en_rev 00 docx page 13 of 24 Figure 5 4 ExCam IPP5635 T08 TNXCD B XXX K L L Figure 5 5 ExCam IPP5635 T08 TNXCD B XXX P L L...

Страница 14: ...v table 5 2 Generally the pins of the same color code are connected Only use SAMCON ap proved clamps It is allowed to separate the ExCam IPP5635 from the network and to switch it on again while in ope...

Страница 15: ...of the power supply is not necessary The power supply is executed by the PoE network device via an electronic with intelligent set up The camera as well as the con nection is permanently monitored in...

Страница 16: ...use L 6000 mA T time lag high inrush current 60 W fuse L 6000 mA T time lag high inrush current L 2 BK 2 5 mm2 litz wire 0 VDC GND Table 5 3 Pin assignment supply cable 5 2 3 Tests prior to switching...

Страница 17: ...ion it might be necessary to obtain a work permit clearance When adjusting the camera settings potentially explosive atmosphere must be avoided by any means To allow the camera delivering the best pic...

Страница 18: ...relevant restrictions WARNING DO NOT OPEN IN HAZARDOUS AREA Note Depending on the zone classification it might be necessary to obtain a work permit clearance Even after disconnection of the volt age...

Страница 19: ...case the applicable settings have to be carried out within the menu System Options Ad vanced Plain Config User root Password root 6 1 Browser Support A list with the currently supported web browsers...

Страница 20: ...installed within the same network segment physical subnet as the computer on which the AXIS IP Utility tool is executed For example the ExCam IPP5635 network identification is Axis P5635 E q v figure...

Страница 21: ...intenance measures are necessary they have to be initiated and or executed 8 Repairs and Maintenance Repairs must only be carried out with original parts of SAMCON Prozessleittechnik GmbH Damaged pres...

Страница 22: ...D models All drawings 3D models certificate and more is available in the download area of the product page on our homepage http www samcon eu en products network excam IPP5635 In case of missing techn...

Страница 23: ...Doc ID 160720 PT08BA SS ExCam IPP5635_en_rev 00 docx page 23 of 24 11 Notes...

Страница 24: ...Doc ID 160720 PT08BA SS ExCam IPP5635_en_rev 00 docx page 24 of 24 Schillerstrasse 17 35102 Lohra Altenvers www samcon eu info samcon eu fon 49 6426 9231 0 fax 31...

Отзывы: