6.- OUT OF ORDER
The machine will go out of order when the vital systems fail. In this case, the screen will
show an error message:
ERROR MESSAGES PANEL
ERROR PROBLEM
SOLUTION
ERROR
General error due to
Switch the machine off and on.
unexpected changes in
Adjust power to 5,3v.
the program variables.
ERROR 1 Error in the program
Switch the machine off and on.
memory.
Tighten all the chips of the PCB.
Replace the program memory.
ERROR 2 Problem in the external
Switch the machine off and on.
RAM memory.
Adjust power to 5,3v.
Replace RAM memory.
ERROR 3 Error in the coin selector
Replace coin selector.
due to permanent signal.
10 tracks flat cable in bad condition.
ERROR 4 Error in the tickets
No tickets or jammed ticket.
dispensor.
DET 1
Malfunction in the
Test motors plaque fuse.
front sensor.
Test movement of the carriage (F12).
Test condition of the sensor (F10).
DET 2
Malfunction in the
Test motors plaque fuse.
back sensor.
Test movement of the carriage (F12).
Test condition of the sensor (F10).
DET 3
Malfunction in the
Test motors plaque fuse.
claw micro up.
Test movement of the carriage (F12).
Test condition of the sensor (F10).
DET 5
Malfunction in the
Test motors plaque fuse.
left sensor.
Test movement of the carriage (F12).
Test condition of the sensor (F10).
ALER
Error in the product
Verify that there is not a jammed product.
exit door.
Test condition of the sensor 6 (F10).
BYE
Error due to lack of power Adjust power to 5,3v.
supply in the 5v. source.
Replace power source.
REAR
Remains in this condition
If the carriage reaches the start point, wait for
till the carriage reaches
the message at the display and follow the
the start position.
errors panel.
Or else will show error.
BATT
The machine keeps
Test the power of the 12v y 5v sources.
resetting all the time.
Replace RAM.
ENGLISH 10