3.14 Frame Configuration and Module Compatibility
There are three possible configurations for each Sirius 800 router model in the field. These
configurations are listed in Table 6 Each configuration enables the router to work with
particular input/output modules and controllers.
Table 6 can be used to check if a router frame has been modified and identify which
configuration it is. This can then be used to confirm what level of routing and processing the
frame configuration supports.
Router Frame Configuration
Mark 1 Frame
Mark 2 Frame
Mark 3 Frame
Frame Description:
Standard Unmodified Frame
Original Modified Frame
Standard & Modified Blue Fan
Frame
Frame Supports:
Video Routing Only
(No Video or Audio
Processing)
Video & Audio Routing,
Audio Processing
(No Video Processing)
Video & Audio Routing,
Video & Audio Processing
Modules:
Router
Controller(s)
Nucleus 2450
Nucleus2 2464/2463
Nucleus2 2464/2463
Fan-Out
Controller(s)
Sirius 830
: 2453
Sirius 840/850
: 2452
Sirius 830
: 2455
Sirius 840/850
: 2456
Sirius 830
: 2457
(blue boards)
Sirius 840/850
: 2458 (blue
boards)
Fans
Silver fan casings (front and
rear) with no letters stamped
on them
Silver fan casings, rear fan
casings stamped
with “HF”
Front and rear fans with blue
fan casings
MV-8x0
Integrated
Multiviewer(s)
Not compatible
Not compatible
Frame operating temperature
range is reduced.
See Table 130 in Appendix
Table 6 Router Frame Configuration
WARNING:
•
DO NOT fit Blue Control/Fan Interface modules (2457/2458) in a router equipped
with fans with Silver casings because this will damage the router and the router will
stop working.
WARNING:
•
DO NOT fit Green Control/Fan Interface modules (2455/2456/2452/2453) in a
router equipped with fans with Blue casings because this will damage the router
and the router will stop working.
WARNING:
•
Fit MV-8x0 Integrated Multiviewers to Sirius 800 Mark 3 Frames only.
Caution:
•
Mark 3 Frame operating temperature range is reduced when one or more MV-8x0
Integrated Multiviewers are fitted.
See Table 130 in Appendix D.4.4 “All Sirius Frames” on page 365,